If2 Invert Connector-Binector Converter Binector Output; Ci: If2 Connector-Binector Converter Signal Source / Con/Bin S_Src; Ie Name Of Station / Ie Name Stat - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Dependency:
Refer to: p8898, p8899
p8898[0...1]
IF2 invert connector-binector converter binector output / Con/bin outp inv
B_INF, CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Communications
CU_G150_PN, ENC,
Not for motor type: -
VECTOR_G
Min
-
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p8898[0], the signals of CI: p8899[0] are influenced.
Using p8898[1], the signals of CI: p8899[1] are influenced.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dependency:
Refer to: r8894, r8895, p8899
p8899[0...1]

CI: IF2 connector-binector converter signal source / Con/bin S_src

B_INF, CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32 / Integer16
CU_G150_DP,
P-Group: Communications
CU_G150_PN, ENC,
Not for motor type: -
VECTOR_G
Min
-
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on
(interconnection).
Dependency:
Refer to: r8850, r8894, r8895, p8898
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p8899[0...1] together with r8894.0...15 and r8895.0...15 forms two connector-binector converters:
Connector input p8899[0] to binector output in r8894.0...15
Connector input p8899[1] to binector output in r8895.0...15
p8900[0...239]

IE Name of Station / IE Name Stat

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Sets the station name for the Industrial Ethernet interface (X127) on the Control Unit.
The active station name is displayed in r8910.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2485, 2491
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Access level: 3
Func. diagram: 2485, 2491
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
819

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents