p3806[0...n]
Sync-line-drive frequency difference threshold value / Sync f_diff thresh
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: -
Min
0.00 [Hz]
Description:
Sets the threshold value of the frequency difference to activate the closed-loop phase control for line-drive
synchronization.
The closed-loop phase control is activated (r3819.6 = 1), if the frequency difference is less that the threshold value.
r3808
CO: Sync-line-drive phase difference / Sync phase diff
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: -
Min
- [°]
Description:
Displays the phase difference between the measured target phase and phase of the gating unit of the closed-loop
control for line-drive synchronization.
p3809[0...n]
Sync-line-drive phase setpoint / Sync phase setp
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: -
Min
-180.00 [°]
Description:
Sets the phase setpoint for the line-drive synchronization.
p3811[0...n]
Sync-line-drive frequency limiting / Sync f_lim
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: -
Min
0.00 [Hz]
Description:
Sets the frequency limiting of the phase controller output for the line-drive synchronization.
r3812
CO: Sync-line-drive correction frequency / Sync f_corr
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: -
Min
- [Hz]
Description:
Displays the correction frequency for the line-drive synchronization.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
1.00 [Hz]
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2005
Max
- [°]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
179.90 [°]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
1.00 [Hz]
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2000
Max
- [Hz]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7020
Unit selection: -
Expert list: 1
Factory setting
0.10 [Hz]
Access level: 2
Func. diagram: 7020
Unit selection: -
Expert list: 1
Factory setting
- [°]
Access level: 2
Func. diagram: 7020
Unit selection: -
Expert list: 1
Factory setting
0.00 [°]
Access level: 2
Func. diagram: 7020
Unit selection: -
Expert list: 1
Factory setting
0.20 [Hz]
Access level: 2
Func. diagram: 3080, 7020
Unit selection: -
Expert list: 1
Factory setting
- [Hz]
579