Siemens SINAMICS G150 Manual page 653

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

18:
19:
20:
21:
22:
30:
35:
36:
37:
38:
39:
Dependency:
Refer to: p4690, p4692, p4693
Notice:
Once SMI/DQI data has been deleted or downloaded successfully, the component has to be powered up.
Note:
SMI: SINAMICS Sensor Module Integrated
DQI: DRIVE-CLiQ Sensor Integrated
Help for error value = 11:
- Save the data for the original SMI on the memory card.
- Use an SMI with a suitable hardware version.
Help for error value = 12:
- Set the correct component number or connect the component.
Help for error value = 13:
- Use a memory card with more memory space.
Help for error value = 14:
- Create a data backup on the memory card corresponding to the SMI type.
Help for error value = 15:
- Check the DRIVE-CLiQ wiring for the component.
Help for error value = 16:
- Check the DRIVE-CLiQ wiring for the component.
Help for error value = 17:
- Save the data for the original SMI on the memory card.
Help for error value = 18:
- Set parameter p4693 to an appropriate value.
Help for error value = 19:
- Perform an SMI delete or use a blank SMI.
Help for error value = 20:
- Use an SMI that is not blank.
Help for error value = 21:
- Set the correct component number (p4690).
Note for error value = 22:
- Data cannot be downloaded for component.
Help for error value = 35:
- Reset parameter p4691 to 30.
Help for error value = 37:
- Set the access level to Expert or higher.
Help for error value = 38:
- Insert the SMI/DQI into the actual topology as an additional component (component number >= 200).
- Set the component number from the actual topology (p4690 >= 200).
- Set the correct component number (p4690 >= 200).
Note for error value = 39:
- SMI already deleted or too old. Delete not possible.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Data backup directory not permissible
Component already contains data
Component does not contain any data
Component is not an SMI or a DQI
SMI data cannot be downloaded for component
Delete SMI data
Confirmation of SMI data delete required
SMI data deleted and POWER ON required for component
Access level not sufficient for delete
Delete SMI data not permitted for component
SMI data for component cannot be deleted
2 Parameters
2.2 List of parameters
653

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents