r2134[0...63]

Alarm value for float values / Alarm value float

All objects
Can be changed: -
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays additional information about the active alarm for float values.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2145, r2146, r3121, r3123
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2135.0...15

CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2

All objects
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Display and BICO output for the second status word of faults and alarms.
Bit field:
Bit
00
01
02
12
13
14
15
r2136[0...63]

Fault time removed in days / t_flt resolv days

All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the system runtime in days when the fault was removed.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2114, r2130, r2133, r3115, r3120, r3122
Notice:
The time comprises r2136 (days) and r2109 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2138.7...15

CO/BO: Control word faults/alarms / STW fault/alarm

All objects
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Display and BICO output for the control word of faults and alarms.
Bit field:
Bit
07
10
11
12
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Fault encoder 1
Fault encoder 2
Fault encoder 3
Fault motor overtemperature
Fault power unit thermal overload
Alarm motor overtemperature
Alarm power unit thermal overload
Signal name
Acknowledge fault
External alarm 1 (A07850) effective
External alarm 2 (A07851) effective
External alarm 3 (A07852) effective
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 8065
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 2548
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 2546
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
FP
-
-
-
8016
8014
8016
8014
FP
8060
8065
8065
8065
513