Avaya S8700 Maintenance Manual page 2203

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

SNI-BD (SNI Circuit Pack)
Table 8-581. TEST #767 Packet Neighbor Link Test — Continued
Error
Test
Code
Result
Description / Recommendation
120
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 20 over the
packet path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 20.
2. Using the display errors command, check the error log for other SNI
3. Replace the SNI being tested.
4. Replace the SNI in slot 20.
555-233-143
Use the display errors command to find any SNI-BD errors and use the
display alarms command to determine whether the errors have on-board
alarms. Then, follow the associated repair procedures for the SNI-BD as
described in the Maintenance manual.
circuit packs with SNI-PEER error type 3841. If other SNI circuit packs
have SNI-PEER error type 3841 errors, replace the SNI in slot 20.
Replacing an SNI may be service interrupting. See
Pack)'' on page 8-1429
for the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 3841 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
''SNI-BD (SNI Circuit
Continued on next page
Issue 1 May 2002
8-1481

Advertisement

Table of Contents
loading

Table of Contents