SNI-BD (SNI Circuit Pack)
Table 8-581. TEST #767 Packet Neighbor Link Test — Continued
Error
Test
Code
Result
Description / Recommendation
105
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 5 over the packet
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 5. Use
2. Using the display errors command, check the error log for other SNI
3. Replace the SNI being tested.
4. Replace the SNI in slot 5.
106
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 6 over the packet
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 6. Use
2. Using the display errors command, check the error log for other SNI
3. Replace the SNI being tested.
4. Replace the SNI in slot 6.
555-233-143
the display errors command to find any SNI-BD errors and use the display
alarms command to determine whether the errors have on-board alarms.
Then, follow the associated repair procedures for the SNI-BD as described
in the Maintenance manual.
circuit packs with SNI-PEER error type 769. If other SNI circuit packs have
SNI-PEER error type 769 errors, replace the SNI in slot 5. Replacing an
SNI may be service interrupting. See
8-1429
for the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 769 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
the display errors command to find any SNI-BD errors and use the display
alarms command to determine whether the errors have on-board alarms.
Then, follow the associated repair procedures for the SNI-BD as described
in the Maintenance manual.
circuit packs with SNI-PEER error type 1025. If other SNI circuit packs
have SNI-PEER error type 1025 errors, replace the SNI in slot 6.
Replacing an SNI may be service interrupting.
Pack)'' on page 8-1429
for the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 1025 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
''SNI-BD (SNI Circuit Pack)'' on page
See''SNI-BD (SNI Circuit
Continued on next page