SNI-BD (SNI Circuit Pack)
Table 8-582. TEST #777 Failure Audit — Continued
Error
Test
Code
Result
Description / Recommendation
0
NO
No board was detected by the test.
BOARD
1. Check that board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNI should be reset
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
Clear Firmware Counters (#982)
This test number is used to report unsuccessful results of the clear
firmware-counters command. This is not an actual demand maintenance test. If
the command aborts, refer to the error codes listed for Test #777.
555-233-143
instead of reseating the circuit pack. The reset board command should
almost never be used on an SNI. It may be necessary to use the reset
board command if the SNI circuit pack gets into a mode where it cannot
communicate with software. If an SNI with active errors and alarms is
reset, the errors and alarms may take a while to come back, therefore the
reset board command can mask real problems.
the board and retest.