Avaya S8700 Maintenance Manual page 2209

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

SNI-BD (SNI Circuit Pack)
Table 8-583. TEST #989 SNI Fiber Out of Frame Query — Continued
Error
Test
Code
Result
Description / Recommendation
2306
ABORT
The SNI circuit pack is not responding to test requests sent by software.
1. Run the test led switch-node for the switch node where the SNI resides to
2. If the LEDs on the other boards in the carrier light, but the LEDs on this
3. If none of the LEDs light for the boards in the same carrier as this board, fix
4. Follow the procedure described above, SNI Manual Loopback to determine
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
141
FAIL
The SNI circuit pack has a fiber out of frame condition, but no loss of signal
condition. Also, a lightwave transceiver is connected to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
2. Perform the Fiber Fault Isolation Procedure described in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
555-233-143
verify whether the LEDs on the board light.
board do not light, run test 760 via test board UUCSS l for the active SNC
in this carrier. Wait 5 minutes and then try step 1 one more time. If the
LEDs on this board still do not light, replace this board. Replacing an SNI
may be service interrupting. See
8-1429
for the procedure for replacing an SNI.
any problems associated with the connectivity of this carrier to the server.
a. Check list fiber-link to determine the fiber connections to this carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the associated repair procedures for
any EXP-INTF error entries associated with the controlling
IPSI-connected EPN.
d. Follow the associated repair procedures for any SYNC, SNI-BD,
SNC-BD, FIBER-LK, or SNI-PEER error entries.
whether the circuit pack or the fiber connection is faulty.
connected circuit pack is the other endpoint of the fiber-link if no DS1C
complex is administered (check via list fiber-link). Otherwise, if a DS1C
complex is administered, the connected circuit pack is the DS1C circuit
pack connected to the SNI circuit pack.
''SNI-BD (SNI Circuit Pack)'' on page
Continued on next page
Issue 1 May 2002
8-1487