STRAT-3 (Stratum-3 Clock)
The output of the CI and PAI cards go directly to the TN780 Tone-Clock circuit
pack via two 25-pair amphenol-terminated cables. Every card has red and/or
green LEDs for providing status or alarm indications. The abbreviations used in
the table are defined above except for SRC (source) and PLL (Phase Locked
Loop).
Table 8-585. Stratum-3 Clock LED Indications
Card
Name
PAI
REF A
REF B
ST A
ST B
PWR A
PWR B
CI
FAIL
DS1
CC
SRC ACTIVE
ST3
FAIL
LOCK
REF A
REF B
TOC
FAIL
PORT ALM
ST
INPUT
500'
1000'
1.
Composite Clock (CC) source refers to the protocol used to electrically transfer timing from the Stratum-3
clock to the switch. The Composite Clock source is not relevant to the system.
555-233-143
Color
Indication
Red
Loss of input reference A or CI A failed
Red
Loss of input reference B or CI A failed
Red
Failed Stratum-3 clock A
Red
Failed Stratum-3 clock B
Green
-48VDC A present
Green
-48VDC B present
Red
Card failure
Green
DS1 source present
Green
Composite clock source
Green
Card is currently on-line
Red
Card failure
Red
PLL lost sync with reference or holdover mode
Red
Timing Reference from CI A
Red
Timing Reference from CI B
Red
Card failure
Red
Output port alarm (one or more)
Green
Reference present from ST clock
Green
Reference present from CI
Green
500-foot phase advance
Green
1000-foot phase advance
1
present