Avaya DEFINITY Server CSI Maintenance Manual page 256

Table of Contents

Advertisement

Maintenance Commands
When the number of call progress tone receivers in service falls
Minimum
Threshold for
below this number (2 to 100), a WARNING alarm is raised against
CPTRs
TTR-LEV. These are also known as general purpose tone detectors
(GPTDs). There are 8 CPTRs on each TN2182. To alarm the first
occurrence of a CPTR being taken out of service, set this field to the
total number of CPTRs in the system.
When the number of call classifier ports (CLSFY-PTs) in service falls
Minimum
Threshold for
below this number, a WARNING alarm is raised against TTR-LEV.
Call Classifier
Valid entries are 1 to 200. There are 8 ports on each TN2182 circuit
Ports
pack. To alarm the first occurrence of a CLSFY-PT being taken out
of service, set this field to the total number of CLSFY-PTs.
An extension assigned to receive tie-trunk calls from other switches
Test Type 100,
Test Type 102,
with test line origination capability. The system responds by sending
Test Type 105
a sequence of test tones. Test Type 100 tests far-end to near-end
loss and C-message by sending:
The extension used by a far-end ISDN node to place a call to the
ISDN-PRI Test
Call Extension
system to test the ISDN-PRI trunks between the far-end and the
system.
This field shows whether or not the link is associated with the Service
ISDN-BRI Service
SPID
SPID. If the link is associated with the Service SPID, this field
contains a "yes" and the extension field is blank. Otherwise, this field
is blank. Service SPID is used by the system technician to check
building wiring between the system and the BRI endpoint.
256
Issue 5 October 2002
5.5 seconds of 1004 Hz tone at 0dB
Quiet until disconnect; disconnect is forced after one minute
555-233-119