Maintenance Commands
Most off-the-shelf external modems provide a timer that abandons
No Answer
Time-Out
any outbound data call after a predetermined interval. Some
modems provide for this timer to be disabled, thus allowing an
outbound call to ring indefinitely. AT&T Paradyne does not provide
this capability with their modem line, because it is generally
undesirable to have an outbound call attempt ring indefinitely.
The internal modem must have this parameter disabled or set to at
least 255 seconds.
This is a non-administrable parameter. For the external modem
connection, this parameter will be the first initialization string to be
transmitted to the external modem. This field will be visible on the
administration form in display mode only.
This hardcoded constant can be overridden for type approval
applications, specifically in the U.K and other Western European
nations, by the use of the "Misc. Init. Param:" field. (S7=255)

display test-schedule

Use display test-schedule to run the Automatic Transmission Measurement
System (ATMS). This provides advanced maintenance procedures for monitoring
system trunk facilities. This system performs transmission tests on system trunks
to determine if trunks are performing satisfactorily. These tests can be initiated in
two ways:
demand
scheduled
Output
The following is the output from display test-schedule n.
260
Issue 5 October 2002
user enters command at the System Administration Terminal
(SAT) to initiate a test immediately
schedules tests through a schedule form to automatically initiate
tests at a predetermined time