:POWer:SIGNals:OVERshoot

Command Syntax
:POWer:SIGNals:OVERshoot <percent>
<percent> ::= percent of overshoot value in NR1 format
The :POWer:SIGNals:OVERshoot command specifies the percent of
overshoot of the output voltage. This value is used to determine the
settling band value for the transient response and to adjust the vertical
scale of the oscilloscope.
Query Syntax
:POWer:SIGNals:OVERshoot?
The :POWer:SIGNals:OVERshoot query returns the overshoot percent
setting.
Return Format
<percent><NL>
<percent> ::= percent of overshoot value in NR1 format