:SEARch:SERial:LIN:MODE

Command Syntax
:SEARch:SERial:LIN:MODE <value>
<value> ::= {ID | DATA | ERRor}
The :SEARch:SERial:LIN:MODE command selects the type of LIN
information to find in the Lister display:
• ID — searches for a frame ID.
• DATA — searches for a frame ID and data.
• ERRor — searches for errors.
Frame IDs are specified using the :SEARch:SERial:LIN:ID command.
Data values are specified using the:SEARch:SERial:LIN:PATTern:DATA
command.
Query Syntax
:SEARch:SERial:LIN:MODE?
The :SEARch:SERial:LIN:MODE? query returns the currently selected mode.
Return Format
<value><NL>
<value> ::= {ID | DATA | ERR}
See Also
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
(see
page
1208)
Chapter
29, ":SEARch Commands," starting on page 817
":SEARch:SERial:LIN:ID"
":SEARch:SERial:LIN:PATTern:DATA"
on page 874
on page 876