These :MEASure commands are available when the DSOX4PWR power
measurements and analysis application is licensed and enabled.
Table 97 :MEASure Power Commands Summary
Command
:MEASure:ANGLe
[<source1>][,<source2
>] (see
page
489)
:MEASure:APParent
[<source1>][,<source2
>] (see
page
490)
:MEASure:CPLoss
[<source1>][,<source2
>] (see
page
491)
:MEASure:CRESt
[<source>] (see
page
492)
Agilent InfiniiVision 4000 X-Series Oscilloscopes
Programmer's Guide
22
:MEASure Power Commands
Query
:MEASure:ANGLe?
[<source1>][,<source2
>] (see
page
489)
:MEASure:APParent?
[<source1>][,<source2
>] (see
page
490)
:MEASure:CPLoss?
[<source1>][,<source2
>] (see
page
491)
:MEASure:CRESt?
[<source>] (see
page
492)
s1
Options and Query Returns
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the power
phase angle in degrees in NR3
format
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the apparent
power value in NR3 format
<source1>, <source2>
<source1> ::= {FUNCtion<m> |
MATH<m>}
<source2> ::= {CHANnel<n>}
<m> ::= 1-4 in NR1 format
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the switching
loss per cycle watts value in NR3
format
<source> ::= {CHANnel<n>|
FUNCtion<m> | MATH<m>}
<n> ::= 1 to (# analog channels)
in NR1 format
<m> ::= 1-4 in NR1 format
<return_value> ::= the crest
factor value in NR3 format