:POWer:HARMonics:APPLy
Command Syntax
:POWer:HARMonics:APPLy
The :POWer:HARMonics:APPLy command applies the current harmonics
analysis.
Switching power supplies draw a range of harmonics from the AC mains.
Standard limits are set for these harmonics because these harmonics can
travel back to the supply grid and cause problems with other devices on
the grid.
Use the Current Harmonics analysis to test a switching power supply's
current harmonics to pre- compliance standard of IEC61000- 3- 2 (Class A,
B, C, or D). The analysis presents up to 40 harmonics.
See Also
•
•
•
•
•
•
•
•
•
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
(see
page
1208)
":POWer:HARMonics:DATA"
":POWer:HARMonics:DISPlay"
":POWer:HARMonics:FAILcount"
":POWer:HARMonics:LINE"
":POWer:HARMonics:POWerfactor"
":POWer:HARMonics:STANdard"
":POWer:HARMonics:STATus"
":POWer:HARMonics:RUNCount"
":POWer:HARMonics:THD"
on page 556
on page 557
on page 558
on page 559
on page 560
on page 562
on page 563
on page 561
on page 564
25
:POWer Commands
555