Command Syntax
:WGEN<w>:ARBitrary:INTerpolate {{0 | OFF} | {1 | ON}}
<w> ::= 1 or 2 in NR1 format
The :WGEN<w>:ARBitrary:INTerpolate command enables or disables the
Interpolation control.
Interpolation specifies how lines are drawn between arbitrary waveform
points:
• When ON, lines are drawn between points in the arbitrary waveform.
• When OFF, all line segments in the arbitrary waveform are horizontal.
Query Syntax
:WGEN<w>:ARBitrary:INTerpolate?
The :WGEN<w>:ARBitrary:INTerpolate query returns the current
interpolation setting.
Return Format
{0 | 1}