Agilent Technologies 8960 Series Operation Manual

Agilent Technologies 8960 Series Operation Manual

10 wireless communications test set
Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

Quick Links

Agilent Technologies 8960 Series 10 Wireless Communications Test Set
Manual Operation: Getting Started Guide
AMPS/136 Mobile Test Application E1961A Revision: A.05
cdma2000 Mobile Test Application E1962B Revision: B.02
GPRS Mobile Test Application E1964A Revision: A.02
GSM Mobile Test Application E1960A Revision: A.08
GSM_AMPS/136_GPRS Mobile Test Application (fast switching) E1985A Revision: A.02
Agilent Part Number: 5967-5172
Print Date: September 2001
© Copyright Agilent Technologies 2001
www.agilent.com/find/8960support/
s1

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 8960 Series

  • Page 1 Agilent Technologies 8960 Series 10 Wireless Communications Test Set Manual Operation: Getting Started Guide AMPS/136 Mobile Test Application E1961A Revision: A.05 cdma2000 Mobile Test Application E1962B Revision: B.02 GPRS Mobile Test Application E1964A Revision: A.02 GSM Mobile Test Application E1960A Revision: A.08 GSM_AMPS/136_GPRS Mobile Test Application (fast switching) E1985A Revision: A.02...
  • Page 2 Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies Inc. assumes no liability for the customer’s failure to comply with these requirements.
  • Page 3 ENVIRONMENTAL CONDITIONS This instrument is intended for indoor use in an installation category II, pollution degree 2 environment. It is designed to operate at a maximum relative humidity of 95% and at altitudes of up to 2000 meters. Refer to the specifications tables for the ac mains voltage requirements and ambient operating temperature range.
  • Page 4 WARNING The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met.
  • Page 5 CSA - the CSA mark is a registered trademark of the Canadian Standards Association. CERTIFICATION Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institute’s calibration facility,...
  • Page 6 3. Agilent Technologies does not warrant that the operation of Agilent Technologies products will be uninterrupted or error free. If Agilent Technologies is unable, within a reasonable time, to repair or replace any product to a condition as warranted, customer will be entitled to a refund of the purchase price upon prompt return of the product.
  • Page 7 MERCHANTABILITY, SATISFACTORY QUALITY, AND FITNESS FOR A PARTICULAR PURPOSE. 8. Agilent Technologies will be liable for damage to tangible property per incident up to the greater of $300,000 or the actual amount paid for the product that is the subject of the...
  • Page 8 Service and Support Any adjustment, maintenance, or repair of this product must be performed by qualified personnel. Contact your customer engineer through your local Agilent Technologies Service Center. You can find a list of local service representatives on the Web at: http://www.agilent-tech.com/services/English/index.html If you do not have access to the Internet, one of these centers can direct you to your nearest representative:...
  • Page 9 United States of America: Agilent Technologies (tel) 1 800 452 4844 Test and Measurement Call Center P.O. Box 4026 Englewood, CO 80155-4026 Canada: Agilent Technologies Canada Inc. (tel) 1 877 894 4414 2660 Matheson Blvd. E Mississauga, Ontario L4W 5G1 Europe: Agilent Technologies...
  • Page 10 Australia/New Zealand: Agilent Technologies Australia Pty Ltd. Australia New Zealand 347 Burwood Highway (tel) 1 800 629 485 (tel) 0 800 738 378 Forest Hill, Victoria 3131 (fax) (61 3) 9272 0749 (fax) (64 4) 802 6881 Asia Pacific: Agilent Technologies(tel) (852) 3197 7777...
  • Page 11 W. V. Roland / Reliability & Regulatory Engineering Manager For further information, please contact your local Agilent Technologies sales office, agent or distributor. Authorized EU-representative: Agilent Technologies Deutschland, GmbH, Herrenberger Strabe 130, D 71034 Boblingen, Germany S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\titlepage.fm...
  • Page 12 W. V. Roland / Reliability & Regulatory Engineering Manager For further information, please contact your local Agilent Technologies sales office, agent or distributor. Authorized EU-representative: Agilent Technologies Deutschland, GmbH, Herrenberger Strabe 130, D 71034 Boblingen, Germany S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\titlepage.fm...
  • Page 13 W. V. Roland / Reliability & Regulatory Engineering Manager For further information, please contact your local Agilent Technologies sales office, agent or distributor. Authorized EU-representative: Agilent Technologies Deutschland, GmbH, Herrenberger Strabe 130, D 71034 Boblingen, Germany S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\titlepage.fm...
  • Page 14 Manufacturer’s Declaration This statement is provided to comply with the requirements of the German Sound Emission Directive, from 18 January 1991. This product has a sound pressure emission (at the operator position) < 70 dB(A). • Sound Pressure Lp < 70 dB(A). •...
  • Page 15: Table Of Contents

    Contents AMPS/136 Mobile Test Application ........21 How Do I Make Measurements on a Mobile? .
  • Page 16 Contents cdma2000 Mobile Test Application ........47 How Do I Make Measurements on a Mobile Station? .
  • Page 17 Contents Measuring Frame Error Rate (FER) ........76 Measuring TDSO (Test Data Service Option) Frame Error Rate (FER) .
  • Page 18 Contents GPRS Mobile Measurements ......... . . 103 Measuring Transmit Power .
  • Page 19 Contents Measuring Fast Bit Error ..........148 Measuring Bit Error .
  • Page 20 Contents...
  • Page 21: Amps/136 Mobile Test Application

    AMPS/136 Mobile Test Application AMPS/136 Mobile Test Application S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 22: How Do I Make Measurements On A Mobile

    How Do I Make Measurements on a Mobile? How Do I Make Measurements on a Mobile? A. Establish a call. 1. Press the blue key. SHIFT 2. Press the green key. PRESET 3. Connect the mobile to the RF IN/OUT port. 4.
  • Page 23: Select Measurements

    How Do I Make Measurements on a Mobile? B. Select measurements. The gray boxes indicate that the measurement is being made, but the results are not being These black boxes indicate that adjacent channel power measurement results are being displayed in the lower measurement window, and frequency modulation measurement...
  • Page 24: How Do I Change Measurement Setup

    How Do I Change Measurement Setup? How Do I Change Measurement Setup? A. Select a measurement. 1. Press the key. Measurement selection 2. Highlight a measurement to setup (the measurement must already be enabled) and press the knob. B. Set up the measurement. 1.
  • Page 25 How Do I Change Measurement Setup? 2. Highlight a parameter and press the knob. 3. Enter a value or selection and press the knob. For statistical measurement results, change the Multi-Measurement NOTE Count parameter from Off to a number >1. 4.
  • Page 26: How Do I Turn Off A Measurement

    How Do I Turn Off a Measurement? How Do I Turn Off a Measurement? 1. Press the key. Measurement selection 2. Highlight the measurement you want to turn off. 3. Press the Close Measurement ( ) key. 4. Press the Close Menu ( ) key.
  • Page 27: How Do I Change Call Parameters

    How Do I Change Call Parameters? How Do I Change Call Parameters? 1. Press the key. CALL SETUP 2. On the Call Parms menu (1 of 2) press 3. Enter a value or highlight a selection and press the knob. 4.
  • Page 28: How Do I Change Cell Parameters

    How Do I Change Cell Parameters? How Do I Change Cell Parameters? Cell parameters specify the information sent to the mobile to identify the cell and to tell the mobile to report mobile assisted handoff (MAHO) information. 1. Press the key.
  • Page 29: How Do I Change The Ms Tx Level

    How Do I Change the MS TX Level? How Do I Change the MS TX Level? There are two ways to change the MS TX Level: A. Change level immediately B. Change level during a handoff Both are explained below. A.
  • Page 30: Change The Ms Tx Level During A Handoff

    How Do I Change the MS TX Level? B. Change the MS TX level during a handoff. 1. On Call Control menu, press the Call/Handoff Setup ( ) key. 2. Select and change the MS TX Level. 3. If you press the Execute Handoff ( ) key, the digital MS TX level changes.
  • Page 31: How Do I Perform A Handoff

    How do I Perform a Handoff? How do I Perform a Handoff? 1. Press the key. CALL SETUP 2. Press the Call/Handoff Setup ( ) key. 3. Select the type of channel to hand off to (AVC or DTC). 4. Change the various parameters for the AVC or DTC. 5.
  • Page 32: How Do I Configure The Test Set For My Test System

    How Do I Configure the Test Set for My Test System? How Do I Configure the Test Set for My Test System? A. Configure instrument information and setup. Test Application Revision 1. Press the key. SYSTEM CONFIG 2. Press the Instrument Setup ( ) key.
  • Page 33: Set Amplitude Offsets

    How Do I Configure the Test Set for My Test System? B. Set amplitude offsets. 1. On the Configuration Summary Screen, press the RF IN/OUT Amptd Offset ) key. 2. On the RF IN/OUT Amplitude Offset screen, press the RF IN/OUT Amptd Offset Setup ( ) key.
  • Page 34: Check The Message Log

    How Do I Configure the Test Set for My Test System? C. Check the message log. 1. Press the Message Log ( ) key and view the message log. 2. Press theReturn to Utilities ( ) key. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\is136_gen_op_overview_sys_config.fm...
  • Page 35: How Do I End A Call

    How Do I End a Call? How Do I End a Call? 1. Press the key. CALL SETUP 2. Press the End Call ( ) key, or end the call from the mobile. 3. Check for Idle in the Active Cell Status: field. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 36: Amps/136 Mobile Measurements

    AMPS/136 Mobile Measurements AMPS/136 Mobile Measurements The following step-by-step procedures explain how to perform specific measurements available on the AMPS/136 Test Application. A detailed description of each measurement is given in the Reference information on the documentation CD-ROM and at the Agilent 8960 support website (www.agilent.com/find/8960support). Setup parameters for each measurement are assumed to be set to their default (full preset) values unless otherwise stated.
  • Page 37: Measuring Digital Transmit Power

    AMPS/136 Mobile Measurements Measuring Digital Transmit Power This measurement can only be performed with the mobile on a digital traffic channel. 1. Establish a call with the mobile on a digital traffic channel. 2. Press the key. Measurement selection 3. Select the Digital Transmit Power measurement. 4.
  • Page 38: Measuring Modulation Accuracy

    AMPS/136 Mobile Measurements Measuring Modulation Accuracy This measurement can only be performed with the mobile on a digital traffic channel. 1. Establish a call with the mobile on a digital traffic channel. 2. Press the key. Measurement selection 3. Select the Modulation Accuracy measurement. 4.
  • Page 39: Measuring Adjacent Channel Power

    AMPS/136 Mobile Measurements Measuring Adjacent Channel Power This measurement can only be performed with the mobile on a digital traffic channel. 1. Establish a call with the mobile on a digital traffic channel. 2. Press the key. Measurement selection 3. Select the Adjacent Channel Power measurement. 4.
  • Page 40: Measuring Bit Error Ratio

    AMPS/136 Mobile Measurements Measuring Bit Error Ratio This measurement can only be performed with the mobile on a digital traffic channel in DTC Test mode. 1. Establish a call on a digital traffic channel in test mode. a. Set the test set’s Operating Mode ( ) to DTC Test.
  • Page 41: Measuring Iq Tuning

    AMPS/136 Mobile Measurements Measuring IQ Tuning This measurement can only be performed with the mobile on a digital traffic channel. 1. Establish a call on a digital traffic channel. If the mobile is configured in test mode, which is typically the case for this measurement, use the following steps: a.
  • Page 42 AMPS/136 Mobile Measurements 9. Change the settings on the mobile to transmit a repeating pattern of 10 (10, 10, 10,...). The results are displayed on the IQ Tuning screen. Notice that when the mobile is transmitting a repeating pattern of 10 the carrier offset is at -3037.50 Hz. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\is136_man_measurements.fm...
  • Page 43: Measuring Analog Transmit Power

    AMPS/136 Mobile Measurements Measuring Analog Transmit Power This measurement can only be performed with the mobile on an analog voice channel (AVC). 1. Establish a call with the mobile on an analog voice channel. 2. Press the key. Measurement selection 3.
  • Page 44: Measuring Frequency Stability

    AMPS/136 Mobile Measurements Measuring Frequency Stability This measurement can only be performed with the mobile on an analog voice channel (AVC). 1. Establish a call with the mobile on an analog voice channel. 2. Press the key. Measurement selection 3. Select the Frequency Stability measurement. 4.
  • Page 45: Measuring Frequency Modulation

    AMPS/136 Mobile Measurements Measuring Frequency Modulation This measurement can only be performed with the mobile on an analog voice channel (AVC). 1. Establish a call with the mobile on an analog voice channel. 2. Press the key. Measurement selection 3. Select the Frequency Modulation measurement. 4.
  • Page 46 AMPS/136 Mobile Measurements S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\is136_man_measurements.fm...
  • Page 47: Cdma2000 Mobile Test Application

    cdma2000 Mobile Test Application cdma2000 Mobile Test Application S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 48: How Do I Make Measurements On A Mobile Station

    How Do I Make Measurements on a Mobile Station? How Do I Make Measurements on a Mobile Station? A. Establish a call. 1. Connect the mobile station to the Test Set. 2. Make a call (see “How Do I Set Up a Call?” on page 52).
  • Page 49: How Do I Change The Measurement Setup

    How Do I Change the Measurement Setup? How Do I Change the Measurement Setup? A. Select a measurement. 1. Press the key. Measurement selection 2. Highlight a measurement to set up and press the knob. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 50: Set Up The Measurement

    How Do I Change the Measurement Setup? B. Set up the measurement. 1. Press the key. MEASUREMENT 2. Press the Control ( ) key to display the measurement’s setup menu. 3. Highlight a parameter and press the knob. 4. Enter a value or selection and press the knob. NOTE For statistical measurement results, highlight the Multi-Measurement Count parameter and press the ON key.
  • Page 51: How Do I Turn Off A Measurement

    How Do I Turn Off a Measurement? How Do I Turn Off a Measurement? 1. Press the key. Measurement selection 2. Use the knob to highlight the measurement you want to turn off. 3. Press Close Measurement ( 4. Press Close Menu ( S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 52: How Do I Set Up A Call

    How Do I Set Up a Call? How Do I Set Up a Call? • “How Do I Set Up an IS-2000 Call?” on page 52 • “How Do I Set Up an IS-95 Call?” on page 54 How Do I Set Up an IS-2000 Call? The Call Parms keys and Call Control keys provide access to the parameters needed to set up a call.
  • Page 53 How Do I Set Up a Call? 6. Press the FCH Service Option Setup ( ) key and set the service option for the radio configurations you plan on testing. SO55 (Service Option 55) is not supported by some mobile stations. If NOTE your mobile station does not support SO55 calls cannot be connected, and you will need to select one of the other loopback or echo service...
  • Page 54: How Do I Set Up An Is-95 Call

    How Do I Set Up a Call? How Do I Set Up an IS-95 Call? 1. Press the key. CALL SETUP 2. Press the Operating Mode ( ) key and set the operating mode to Active Cell. 3. Press the System Type ( ) key and select IS-95.
  • Page 55 How Do I Set Up a Call? 11.Make a mobile station originated call (by entering a phone number and pressing SEND on the mobile station handset), or wait for the mobile station to perform a power up registration and press the Originate Call ( ) key.
  • Page 56: How Do I Change Call Parameters

    How Do I Change Call Parameters? How Do I Change Call Parameters? 1. Press the key. CALL SETUP 2. On the Call Parms menu (1 of 2) press any key. 3. Highlight a selection and press the knob. Enter a value. 4.
  • Page 57: How Do I Change Cell Information

    How Do I Change Cell Information? How Do I Change Cell Information? There are three types of cell information: cell parameters, access parameters, and registration parameters. A. Set cell parameters. 1. Select the Cell Parameters menu. 1. Press the key. CALL SETUP 2.
  • Page 58 How Do I Change Cell Information? 2. Set a cell parameter. 1. Turn the knob to highlight a parameter and then press the knob. 2. Enter a value or selection and press the knob. 3. Press the Close Menu ( ) key.
  • Page 59: Set Access Parameters

    How Do I Change Cell Information? B. Set access parameters. 1. Select the Access Parameters menu. 1. Press the key. CALL SETUP 2. Press the key. More 3. Press the Cell Info ( ) key. 4. Press the Access Parameters ( ) key.
  • Page 60 How Do I Change Cell Information? 2. Set an access parameter. 1. Turn the knob to highlight a parameter and then press the knob. 2. Enter a value or selection and press the knob. 3. Press the Close Menu ( ) key.
  • Page 61: Set Registration Parameters

    How Do I Change Cell Information? C. Set registration parameters. 1. Select the Registration Parameters menu. 1. Press the key. CALL SETUP 2. Press the key. More 3. Press the Cell Info ( ) key. 4. Press the Registration Parameters ( ) key.
  • Page 62 How Do I Change Cell Information? 2. Set a registration parameter. 1. Turn the knob to highlight a parameter and then press the knob. 2. Enter a value or selection and press the knob. 3. Press the Close Menu ( ) key.
  • Page 63: How Do I Change Code Channel Levels

    How Do I Change Code Channel Levels? How Do I Change Code Channel Levels? 1. Press the key. CALL SETUP 2. Press the key. More 3. Press the Generator Info ( ) key. 4. Press the Code Channel Parameters ) key. 5.
  • Page 64: How Do I Perform A Handoff

    How Do I Perform a Handoff? How Do I Perform a Handoff? 1. On the Call Setup screen, press the Call/Handoff Setup ( ) key. 2. Highlight the Handoff System Type parameter and select the desired system. 3. Highlight the Handoff Cell Band parameter and select the desired band. 4.
  • Page 65: How Do I Configure The Test Set For My Test System

    How Do I Configure the Test Set for My Test System? How Do I Configure the Test Set for My Test System? A. Configure instrument information and setup. Test Application Revision 1. Press the key. SYSTEM CONFIG 2. Press the Instrument Setup ( ) key.
  • Page 66: Set Amplitude Offsets

    How Do I Configure the Test Set for My Test System? B. Set amplitude offsets. 1. On the Configuration Summary screen (not shown), press the RF IN/OUT Amptd Offset ( ) key. 2. On the RF IN/OUT Amplitude Offset screen, press the RF IN/OUT Amptd Offset Setup ( ) key.
  • Page 67: Check Message Log

    How Do I Configure the Test Set for My Test System? C. Check message log. 1. From any System Config screen, press the Message Log ( ) key and view the message log. 2. Press the Return ( ) key. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 68: How Do I End A Call

    How Do I End a Call? How Do I End a Call? 1. Press the key. CALL SETUP 2. Press the End Call ( ) key, or end the call from the mobile. 3. Check for Idle in the Active Cell status field. S:\Hp8960\Generic Documents\Manual Operation...
  • Page 69: Cdma2000 Measurement Procedures

    cdma2000 Measurement Procedures cdma2000 Measurement Procedures The following step-by-step procedures explain how to manually perform specific measurements available on the cdma2000 Test Application. A detailed description of each measurement is given in the Reference information on the documentation CD-ROM and at the Agilent 8960 support website (http://www.agilent.com/find/8960support/).
  • Page 70: Measuring Waveform Quality

    cdma2000 Measurement Procedures Measuring Waveform Quality Each waveform quality measurement returns a number of measurements which includes rho. 1. Select the Waveform Quality/Code Domain measurement (see “B. Select measurements.” on page 48). A typical display is shown below. 2. Set up the measurement parameters as needed for your measurement situation (see “B.
  • Page 71: Measuring Handoff Waveform Quality

    cdma2000 Measurement Procedures Measuring Handoff Waveform Quality Each waveform quality measurement returns a number of measurements which includes rho. These measurements can be made only when one of the following radio configurations (see “How Do I Set Up a Call?” on page 52) is selected: •...
  • Page 72: Measuring Digital Average Power

    cdma2000 Measurement Procedures Measuring Digital Average Power 1. Select the Digital Average Power measurement (see “B. Select measurements.” on page 48). A typical display is shown below. 2. Press the Digital Average Power Setup ( ) key. 3. Set up the measurement parameters as needed for your measurement situation (see “B.
  • Page 73: Measuring Channel Power

    cdma2000 Measurement Procedures Measuring Channel Power 1. Select the Channel Power measurement (see “B. Select measurements.” on page 48). A typical display is shown below. 2. Set up the measurement parameters as needed for your measurement situation (see “B. Set up the measurement.” on page S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 74: Measuring Access Probe Power

    cdma2000 Measurement Procedures Measuring Access Probe Power 1. Press the key. CALL SETUP 2. Press the End Call key ( 3. Select the Access Probe Power measurement (see “B. Select measurements.” on page 48). 4. Press the Register Mobile key ( ).
  • Page 75 cdma2000 Measurement Procedures 10.Press the Originate Call key ( ). Wait for the Access Probe call status indication in the Active Cell field below the measurement window. A typical display is shown below. 11.Turn off call limiting. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 76: Measuring Frame Error Rate (Fer)

    cdma2000 Measurement Procedures Measuring Frame Error Rate (FER) 1. Press the key. Measurement selection 2. Select the Frame Error Rate measurement. 3. Press the Frame Error Rate Setup ( ) key. A typical display is shown below. 4. Set up the measurement parameters as needed for your measurement situation. S:\Hp8960\Generic Documents\Manual Operation...
  • Page 77: Measuring Tdso (Test Data Service Option) Frame Error Rate (Fer)

    cdma2000 Measurement Procedures Measuring TDSO (Test Data Service Option) Frame Error Rate (FER) 1. Press the key. CALL SETUP 2. If a call is currently connected, press the End Call key ( 3. Press the Radio Config key ( 4. Select one of the following radio configurations: •...
  • Page 78 cdma2000 Measurement Procedures 14.Press the TDSO FER Setup ( ) key. 15.Set up the measurement parameters as needed for your measurement situation. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\cdma2000_gen_op_overview_man_measurements.fm...
  • Page 79: Measuring Code Domain Power And Code Domain Power + Noise

    cdma2000 Measurement Procedures Measuring Code Domain Power and Code Domain Power + Noise These measurements can be made only when one of the following radio configurations (see “How Do I Set Up a Call?” on page 52) is selected: • (Fwd3, Rvs3) •...
  • Page 80 cdma2000 Measurement Procedures 2. Press the Code Domain Power ( ) key. A typical display is shown below. The red bars indicate power levels The yellow bars indicate noise levels 3. Press the Graph Control key ( ). Change the value in the Limit field. Note that both green lines, indicating the I and Q channel noise limits, move together.
  • Page 81 cdma2000 Measurement Procedures The red bars indicate power levels The yellow bars indicate noise levels 6. Return to the numeric Rho display at any time by pressing the Numeric Rho key S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 82: Measuring Code Channel Time/Phase Error

    cdma2000 Measurement Procedures Measuring Code Channel Time/Phase Error These measurements can be made only when one of the following radio configurations (see “How Do I Set Up a Call?” on page 52) is selected: • (Fwd3, Rvs3) • (Fwd4, Rvs3) •...
  • Page 83: Measuring Gated Power

    cdma2000 Measurement Procedures Measuring Gated Power These measurements can be made only when one of the following radio configurations (see “How Do I Set Up a Call?” on page 52) is selected: • (Fwd1, Rvs1) • (Fwd2, Rvs2) 1. Select the Gated Power measurement (see “B.
  • Page 84: Measuring Tx Spurious Emissions

    cdma2000 Measurement Procedures Measuring TX Spurious Emissions 1. Select the Tx Spurious Emissions measurement (see “B. Select measurements.” on page 48). A typical display is shown below. 2. Press the Graph ( ) key. NOTE Press the Numeric ( ) key if you want to return to Tx Spurious Emissions measurement results displayed in tables.
  • Page 85: Related Topics

    cdma2000 Measurement Procedures Related Topics Refer to Product Note 5988-1989EN Multi-Coded Waveform Quality and Code Domain Measurements for cdma2000 for more information about Code Domain Power measurements. This is located on the web or CDROM under Technical notes. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 86 cdma2000 Measurement Procedures S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\cdma2000_gen_op_overview_man_measurements.fm...
  • Page 87: Gprs Mobile Test Application

    GPRS Mobile Test Application GPRS Mobile Test Application S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\ch_GPRS.fm...
  • Page 88: How Do I Make Measurements On A Mobile

    How Do I Make Measurements on a Mobile? How Do I Make Measurements on a Mobile? A. Establish a data connection. 1. Press the blue key. SHIFT 2. Press the green key. Preset 3. Connect the mobile. 4. Turn the mobile on and wait for Attached in the Active Cell: field. NOTE For mobiles that don’t perform GPRS attach automatically, set the mobile to data mode.
  • Page 89: Select Measurements

    How Do I Make Measurements on a Mobile? B. Select measurements. The gray boxes indicate that the measurement is being made, but the results are not being displayed. These black boxes indicate that phase and frequency error measurement results are being displayed in the lower measurement window, and bit error measurement results...
  • Page 90: How Do I Change Measurement Setup

    How Do I Change Measurement Setup? How Do I Change Measurement Setup? A. Select a measurement. 1. Press the key. Measurement selection 2. Highlight a measurement to set up and press the knob. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\GPRS_gen_op_overview_meas_setup.fm...
  • Page 91: Set Up The Measurement

    How Do I Change Measurement Setup? B. Set up the measurement. 1. Press the measurement’s setup ( ) key. 2. Highlight a parameter and press the knob. 3. Enter a value or make a selection and press the knob. NOTE For Statistical measurement results, change the Multi-Measurement Count parameter from Off to a number >1.
  • Page 92: How Do I Turn Off A Measurement

    How Do I Turn Off a Measurement? How Do I Turn Off a Measurement? 1. Press the key. Measurement selection 2. Highlight the measurement you want to turn off. 3. Press the Close Measurement ( ) key. 4. Press the Close Menu ( ) key.
  • Page 93: How Do I Change Call Parameters

    How Do I Change Call Parameters? How Do I Change Call Parameters? 1. Press the key. CALL SETUP When the mobile is transferring data (Active Cell: field is NOTE Transferring) some call parameters cannot be changed. 2. On the Call Parms menu (1 of 4) press 3.
  • Page 94: How Do I Change Cell Parameters

    How Do I Change Cell Parameters? How Do I Change Cell Parameters? NOTE You can only change two cell parameters - 3 Digit MNC for PCS1900 and Guard Period Length. Other cell parameters such as MCC, MNC, and LAC are fixed. To change the 3 digit MNC for PCS1900 the cell must be set to off by pressing the key, then Operating CALL SETUP...
  • Page 95: Set A Cell Parameter

    How Do I Change Cell Parameters? B. Set a cell parameter. 1. Highlight a parameter and press the knob. 2. Enter a value or selection and press the knob. 3. Press the Close Menu ( ) key. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 96: How Do I Perform A Handover

    How Do I Perform a Handover? How Do I Perform a Handover? 1. Press the key. CALL SETUP 2. Press the Handover Setup ( ) key. 3. Change the various parameters, for example Traffic Band. 4. Press the Handover Execute ( ) key to complete the handover, or press the Close Menu ( ) key to abort the handover.
  • Page 97: How Do I Change The Ms Tx Level

    How Do I Change the MS TX Level? How Do I Change the MS TX Level? There are two ways to change the MS TX Level: A. Change the level immediately B. Change the level during a handover Both are explained below. A.
  • Page 98: Change The Ms Tx Level During A Handover

    How Do I Change the MS TX Level? B. Change the MS TX level during a handover. 1. Press the key. CALL SETUP 2. On Control menu, press the Handover Setup ( ) key. 3. Select and change the MS TX Level. 4.
  • Page 99: How Do I Configure The Test Set For My Test System

    How Do I Configure the Test Set for My Test System? How Do I Configure the Test Set for My Test System? A. Configure instrument information and setup. Test Application Revision 1. Press the key. SYSTEM CONFIG 2. Press the Instrument Setup ( ) key.
  • Page 100: Set Amplitude Offsets

    How Do I Configure the Test Set for My Test System? B. Set amplitude offsets. 1. On the Configuration Summary screen, press the RF IN/OUT Amptd Offset ( key. 2. On the RF IN/OUT Amplitude Offset screen, press the RF IN/OUT Amptd Offset Setup ( ) key.
  • Page 101: Check The Message Log

    How Do I Configure the Test Set for My Test System? C. Check the message log. 1. Press the Message Log ( ) key and view the message log. 2. Press the Return ( ) key. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 102: How Do I End The Data Connection

    How Do I End the Data Connection? How Do I End the Data Connection? 1. Press the key. CALL SETUP 2. Press the End Data Connection ( ) key, or end the data connection from the mobile. 3. To ensure the data connection has ended check for Attached in the Active Cell: field.
  • Page 103: Gprs Mobile Measurements

    GPRS Mobile Measurements GPRS Mobile Measurements The following step-by-step procedures explain how to perform specific measurements available on the GPRS Test Application. A detailed description of each measurement is given in the Reference information on the documentation CD-ROM and at the Agilent 8960 support website (http://www.agilent.com/find/8960support/).
  • Page 104: Measuring Transmit Power

    GPRS Mobile Measurements Measuring Transmit Power 1. Connect the mobile. 2. Turn the mobile on and wait for Attached in the Active Cell: field. Note: For mobiles that don’t perform a GPRS attach automatically, set the mobile to data mode. 3.
  • Page 105: Measuring Power Versus Time

    GPRS Mobile Measurements Measuring Power versus Time This measurement procedure assumes that your mobile supports two NOTE adjacent uplink timeslots. 1. Press the key. CALL SETUP 2. Press the key (bottom right) to obtain the Call Parms (3 of 4) screen. More 3.
  • Page 106 GPRS Mobile Measurements 14.Press the Close Menu ( ) key. A typical summary results screen is shown above. 15.Press the Return ( ) key. 16.Press the Change View ( ) key. 17.Press the Burst 1 numeric Results ( ) key to view the offset measurement results for burst 1.
  • Page 107 GPRS Mobile Measurements A typical numeric measurement results screen for offsets is shown above. 18.Press the Burst 2 numeric Results ( ) key to view the offset measurement results for burst 2. 19.Press the Graph ( ) key to access the full graph view of the two adjacent uplink bursts.
  • Page 108 GPRS Mobile Measurements Pass/Fail indicators for each section of the uplink bursts Overall Pass/Fail indicator A typical full graph view of two adjacent uplink bursts is shown above. Two types of pass/fail results are provided: • An overall measurement pass/fail indicator is positioned in the bottom left corner of the display: —...
  • Page 109 GPRS Mobile Measurements • Individual pass/fail indicators are provided for each section of the mask. On the display, text labels corresponding to the following sections change color to indicate a pass or fail (green indicates a pass; red indicates a fail): —...
  • Page 110 GPRS Mobile Measurements control a marker or change axis values by pressing the Graph Control ( ) key. Marker signal level and position along the x-axis Marker indicator A typical graph view of the falling edge of burst 2 is shown above. You can access this view by pressing the Burst 2 Views ( ) key then the Falling Edge ( key.
  • Page 111 GPRS Mobile Measurements Power versus Time Graph Menus (one uplink burst) S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 112 GPRS Mobile Measurements Power versus Time Graph Menus (two uplink bursts) S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gprs_man_measurements.fm...
  • Page 113: Measuring Phase And Frequency Error

    GPRS Mobile Measurements Measuring Phase and Frequency Error 1. Connect the mobile. 2. Turn the mobile on and wait for Attached in the Active Cell: field. Note: For mobiles that don’t perform a GPRS attach automatically, set the mobile to data mode. 3.
  • Page 114 GPRS Mobile Measurements 9. Press the Graph ( ) key to access the peak phase error graph. A typical peak phase error graph is shown above. The marker can be turned on by pressing the Graph Control ( ) key then the Marker Position ( ) key.
  • Page 115 GPRS Mobile Measurements Phase and Frequency Error Graph Menus S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 116: Measuring Output Rf Spectrum

    GPRS Mobile Measurements Measuring Output RF Spectrum 1. Connect the mobile. 2. Turn the mobile on and wait for Attached in the Active Cell: field. Note: For mobiles that don’t perform a GPRS attach automatically, set the mobile to data mode. 3.
  • Page 117 GPRS Mobile Measurements The measurement results for the first eight positions in the ORFS due to modulation table are displayed. You can view the results for the remaining 14 positions by pressing the Modulation Numeric 2 of 3 ( ) key or the Modulation Numeric 3 of 3 ( ) key.
  • Page 118 GPRS Mobile Measurements 16.Press the Graph ( ) key then the Modulation ( ) key to access the ORFS due to modulation bar graph. Center frequency Frequency offsets A typical ORFS due to modulation graph is shown above. On the display, the bar representing each offset is shown in yellow and the center frequency is indicated by a red vertical line.
  • Page 119 GPRS Mobile Measurements In this case, the marker is turned on and positioned at the 600 kHz offset. The signal level and frequency of the offset where the marker is positioned, are shown at the top of the display above the graph. The marker can be turned on by pressing the Graph Control ( ) key then the Marker Position (...
  • Page 120 GPRS Mobile Measurements Output RF Spectrum Graph Menus S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gprs_man_measurements.fm...
  • Page 121: Measuring Bit Error

    GPRS Mobile Measurements Measuring Bit Error To make bit error measurements your mobile must be fitted with a Test NOTE SIM card and have ETSI Type B connection capability. 1. Press the key. CALL SETUP 2. Press the key (bottom right) to obtain the Call Parms (3 of 4) screen. More 3.
  • Page 122 GPRS Mobile Measurements Measurement Timeout = 13.0 s Observe how reducing the cell power affects the bit error ratio. A typical bit error ratio measurement result is shown above. To see the effect of cell power on the bit error ratio, press the Cell Power ( ) key on the Call Parms (1 of 3) screen and slowly reduce the power while observing the Bit Error display.
  • Page 123: Gsm Mobile Test Application

    GSM Mobile Test Application GSM Mobile Test Application S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\ch_GSM.fm...
  • Page 124: How Do I Make Measurements On A Mobile

    How Do I Make Measurements on a Mobile? How Do I Make Measurements on a Mobile? A. Establish a call. 1. Press the blue key. SHIFT 2. Press the green key. Preset 3. Connect the mobile. 4. Turn on the mobile and wait for it to camp. NOTE If the mobile does not camp check that it is using the test set default PGSM cell band.
  • Page 125: Select Measurements

    How Do I Make Measurements on a Mobile? B. Select measurements. These black boxes indicate that transmit power measurement results are being displayed in the lower measurement window, and phase and frequency error measurement results are being displayed in the upper measurement window.
  • Page 126: How Do I Change A Measurement's Setup

    How Do I Change a Measurement’s Setup? How Do I Change a Measurement’s Setup? A. Select a measurement. 1. Press the key. Measurement selection 2. Highlight a measurement to set up and press the knob. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gen_op_overview_meas_setup.fm...
  • Page 127: Set Up The Measurement

    How Do I Change a Measurement’s Setup? B. Set up the measurement. 1. Press the measurement’s setup key ( 2. Highlight a parameter and press the knob. 3. Enter a value or make a selection and press the knob. For statistical measurement results, change the Multi-Measurement NOTE Count parameter from Off to a number >1.
  • Page 128: How Do I Turn Off A Measurement

    How Do I Turn Off a Measurement? How Do I Turn Off a Measurement? 1. Press the key. Measurement selection 2. Highlight the measurement you want to turn off. 3. Press the Close Measurement ( ) key. 4. Press the Close Menu ( key.
  • Page 129: How Do I Change Call Parameters

    How Do I Change Call Parameters? How Do I Change Call Parameters? 1. Press the key. CALL SETUP 2. Press , or 3. Enter a value or highlight a selection and press the knob. 4. Press the key for additional call parameters. More NOTE For a dual-band handover, change the Traffic Band selection (Call...
  • Page 130: How Do I Change Cell Parameters

    How Do I Change Cell Parameters? How Do I Change Cell Parameters? A. Select the Cell Parameters menu. 1. Press the key. CALL SETUP 2. Press the Cell Info ( ) key. 3. Press the Cell Parameters ( ) key. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gen_op_overview_cell_parms.fm...
  • Page 131: Set A Cell Parameter

    How Do I Change Cell Parameters? B. Set a cell parameter. • To change “network” cell parameters: 1. Highlight Cell Activated State and press the knob. 2. Set Cell Activated State to Off. (Highlight Off and press the knob.) 3. Set network cell parameter to the desired value. (Highlight the parameter, press the knob, enter a value, and press the knob.) 4.
  • Page 132: How Do I Configure The Test Set For My Test System

    How Do I Configure the Test Set for My Test System? How Do I Configure the Test Set for My Test System? A. Configure instrument information and setup. Test Application Revision 1. Press the key. SYSTEM CONFIG 2. Press the Instrument Setup ( ) key.
  • Page 133: Set Amplitude Offsets

    How Do I Configure the Test Set for My Test System? B. Set amplitude offsets. 1. On the Configuration Summary screen, press the RF IN/OUT Amptd Offset ( key. 2. On the RF IN/OUT Amplitude Offset screen, press the RF IN/OUT Amptd Offset Setup ( ) key.
  • Page 134: Check The Message Log

    How Do I Configure the Test Set for My Test System? C. Check the message log. 1. Press the Message Log ( ) key and view the message log. 2. Press the Return ( ) key. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gen_op_overview_config_testset.fm...
  • Page 135: How Do I End A Call

    How Do I End a Call? How Do I End a Call? 1. Press the key. CALL SETUP 2. Press the End Call ( ) key, or end the call from the mobile. 3. Check for Idle in the Active Cell Status: field. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 136: Gsm Mobile Measurements

    GSM Mobile Measurements GSM Mobile Measurements The following step-by-step procedures explain how to perform specific measurements available on the GSM Test Application. A detailed description of each measurement is given in the Reference information on the documentation CD-ROM and at the Agilent 8960 support website (http://www.agilent.com/find/8960support/).
  • Page 137: Measuring Transmit Power

    GSM Mobile Measurements Measuring Transmit Power 1. Establish a call with the mobile. 2. Press the key. Measurement selection 3. Select the Transmit Power measurement. 4. Press the Transmit Power Setup ( ) key. 5. Set the measurement parameters as needed for your measurement situation, including: Measurement Timeout = 5.0 s Mobile’s reported...
  • Page 138: Measuring Power Versus Time

    GSM Mobile Measurements Measuring Power versus Time 1. Establish a call with the mobile. 2. Press the key. Measurement selection 3. Select the Power vs Time measurement. 4. Press the Power vs Time Setup ( )key. 5. Press the Measurement Setup ( )key.
  • Page 139 GSM Mobile Measurements The displayed screen shows whether the burst is within the Mask (Pass or Fail), broad-band carrier Transmit Power, the Upper Limit Margin, and the Lower Limit Margin. 10.Press the Return to PvT Control ( ) key. 11.Press the Change View ( ) key.
  • Page 140 GSM Mobile Measurements A typical numeric measurement results screen for offsets 1 through 6 is shown above. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gsm_man_measurements.fm...
  • Page 141 GSM Mobile Measurements 13.Press the Graph ( ) key to access the full graph of the uplink burst. Overall Pass/Fail indicator A typical full graph view of the burst is shown above. An overall pass/fail indicator is positioned in the bottom left corner of the display: •...
  • Page 142 GSM Mobile Measurements You can zoom in to individual sections of the graph by pressing the Full ( Rising Edge ( ), Falling Edge ( ), or Useful ( ) keys. In addition, you can control a marker or change axis values by pressing the Graph Control ( ) key.
  • Page 143: Power Versus Time Graph Menus

    GSM Mobile Measurements Power versus Time Graph Menus S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 144: Measuring Phase And Frequency Error

    GSM Mobile Measurements Measuring Phase and Frequency Error 1. Establish a call with the mobile. 2. Press the key. Measurement selection 3. Select the Phase & Frequency Error measurement. 4. Press the Phase & Freq. Setup ( ) key. 5. Set the measurement parameters as needed for your measurement situation, including: Measurement Timeout = 10 s A typical phase and frequency error measurement result is shown above.
  • Page 145 GSM Mobile Measurements 7. Press the Graph ( ) key to access the peak phase error graph. Pass/Fail indicators for the peak Overall Pass/Fail indicator phase error, RMS phase error and frequency error A typical peak phase error graph is shown above. Two types of pass/fail results are provided: •...
  • Page 146 GSM Mobile Measurements NOTE When the Multi-Measurement Count parameter is set to a number greater than 1, it is possible for some, or all of the individual pass/fail indicators to show a pass while the overall pass/fail indicator shows a fail.
  • Page 147: Phase And Frequency Error Graph Menus

    GSM Mobile Measurements Phase and Frequency Error Graph Menus S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 148: Measuring Fast Bit Error

    GSM Mobile Measurements Measuring Fast Bit Error To make fast bit error measurements your mobile must be fitted with a NOTE Test SIM card. 1. Establish a call with the mobile. 2. Press the key. Measurement selection 3. Select the Fast Bit Error measurement. You should hear a warbling sound from the mobile’s loudspeaker.
  • Page 149: Measuring Bit Error

    GSM Mobile Measurements Measuring Bit Error To make bit error measurements your mobile must be fitted with a Test NOTE SIM card. 1. Establish a call with the mobile. 2. Press the key. Measurement selection 3. Select the Bit Error measurement. 4.
  • Page 150: Measuring Output Rf Spectrum

    GSM Mobile Measurements Measuring Output RF Spectrum 1. Establish a call with the mobile. 2. Press the key. Measurement selection 3. Select the Output RF Spectrum measurement. 4. Press the ORFS Setup ( ) key. 5. Press the Measurement Setup ( ) key.
  • Page 151 GSM Mobile Measurements 12.Press the Modulation Numeric 1 of 3 ( ) key. The measurement results for the first eight positions in the ORFS due to modulation table are displayed. You can view the results for the remaining 14 positions by pressing the Modulation Numeric 2 of 3 ( ) key or the Modulation Numeric 3 of 3 ( ) key.
  • Page 152 GSM Mobile Measurements 14.Press the Graph ( ) key then the Modulation ( ) key to access the ORFS due to modulation bar graph. Center frequency Frequency offsets A typical ORFS due to modulation graph is shown above. On the display, the bar representing each offset is shown in yellow and the center frequency is indicated by a red vertical line.
  • Page 153 GSM Mobile Measurements In this case, the marker is turned on and positioned at the 600 kHz offset. The signal level and frequency of the offset where the marker is positioned, are shown at the top of the display above the graph. The marker can be turned on by pressing the Graph Control ( ) key then the Marker Position (...
  • Page 154: Output Rf Spectrum Graph Menus

    GSM Mobile Measurements Output RF Spectrum Graph Menus S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gsm_man_measurements.fm...
  • Page 155: Measuring Iq Tuning

    GSM Mobile Measurements Measuring IQ Tuning This measurement can only be performed with your mobile in test mode NOTE and transmitting either all ones or all zeros. 1. Press the key. Measurement selection 2. Select the IQ Tuning measurement. 3. Press the key (bottom right) to obtain the Call Parms (3 of 4) screen.
  • Page 156 GSM Mobile Measurements 9. Change the settings on the mobile to transmit a series of all ones. The results are displayed on the IQ Tuning screen. Notice that when the mobile is transmitting a series of all ones the carrier offset is at -67.708 kHz. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gsm_man_measurements.fm...
  • Page 157 GSM Mobile Measurements 10.Press the Graph ( ) key to access the IQ Tuning bar graph. Frequency offsets Carrier frequency A typical IQ Tuning graph is shown above. On the display, the bar representing each offset and the carrier frequency (Fc) is shown in yellow. If you require details on how to navigate through the Output RF Spectrum graph menus, see “IQ Tuning Graph Menus”...
  • Page 158: Iq Tuning Graph Menus

    GSM Mobile Measurements IQ Tuning Graph Menus S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gsm_man_measurements.fm...
  • Page 159: E1985A Gsm_Amps/136_Gprs Mobile Test Application (Fast Switching)

    E1985A GSM_AMPS/136_GPRS Mobile Test Application (fast switching) E1985A GSM_AMPS/136_GPRS Mobile Test Application (fast switching) S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 160: How Do I Switch Formats

    How Do I Switch Formats? How Do I Switch Formats? A. Choose a format. 1. Press the key. SYSTEM CONFIG 2. Press the Format Switch ( ) key. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gsm_136_fsta_gen_op_overview_switch.fm...
  • Page 161: Switch Formats

    How Do I Switch Formats? B. Switch formats. 1. Turn the knob to highlight the desired format. 2. Press the knob to switch formats. S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 162 How Do I Switch Formats? S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started guide\chapters\gsm_136_fsta_gen_op_overview_switch.fm...
  • Page 163: Switching Test Applications

    Switching Test Applications Switching Test Applications S:\Hp8960\Generic Documents\Manual Operation Getting Started Guide\Pi_manual operation getting started...
  • Page 164: How Do Switch Test Applications

    How Do Switch Test Applications? How Do Switch Test Applications? A. Choose a test application. 1. Press the key. SYSTEM CONFIG 2. Press the Test Application ( ) key. 3. Press the Test Application Switch ( ) key, and wait for the Test Application, Revision, License menu to appear.
  • Page 165: Switch Test Applications

    How Do Switch Test Applications? 4. Turn the knob to highlight a test application name, and press the knob to select the TA. B. Switch test applications. 1. Turn the knob to highlight Yes in the Switch Now? menu. 2. Press the knob to switch test applications. 3.

This manual is also suitable for:

E5515cE5515bE5515t

Table of Contents