:SBUS<n>:CAN:TRIGger:PATTern:ID
Command Syntax
:SBUS<n>:CAN:TRIGger:PATTern:ID <string>
<string> ::= "nn...n" where n ::= {0 | 1 | X | $}
<string ::= "0xnn...n" where n ::= {0,..,9 | A,..,F | X | $}
The :SBUS<n>:CAN:TRIGger:PATTern:ID command defines the CAN
identifier pattern resource according to the string parameter. This pattern,
along with the identifier mode (set by the
:SBUS<n>:CAN:TRIGger:PATTern:ID:MODE command), control the identifier
pattern searched for in each CAN message.
If the string parameter starts with "0x", it is a hexadecimal string made up
of hexadecimal and X (don't care) characters; otherwise, it is a binary
string made up of 0, 1, and X (don't care) characters.
The ID pattern resource string is always 29 bits. Only 11 of these bits are used when the
N O T E
:SBUS<n>:CAN:TRIGger:PATTern:ID:MODE is STANdard.
A string longer than 29 bits is truncated to 29 bits when setting the ID pattern resource.
Query Syntax
:SBUS<n>:CAN:TRIGger:PATTern:ID?
The :SBUS<n>:CAN:TRIGger:PATTern:ID? query returns the current settings
of the specified CAN identifier pattern resource in the 29- bit binary string
format.
Return Format
<string><NL> in 29-bit binary string format
Errors
See Also
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
(see
page
1208)
"- 241, Hardware missing"
"Introduction to :TRIGger Commands"
":SBUS<n>:CAN:TRIGger:PATTern:ID:MODE"
":SBUS<n>:CAN:TRIGger:PATTern:DATA"
on page 1169
on page 935