Agilent Technologies InfiniiVision 4000 X-Series Programmer's Manual page 166

Oscilloscopes
Hide thumbs Also See for InfiniiVision 4000 X-Series:
Table of Contents

Advertisement

5
Common (*) Commands
*ESE (Standard Event Status Enable)
Command Syntax
*ESE <mask_argument>
<mask_argument> ::= integer from 0 to 255
The *ESE common command sets the bits in the Standard Event Status
Enable Register. The Standard Event Status Enable Register contains a
mask value for the bits to be enabled in the Standard Event Status
Register. A "1" in the Standard Event Status Enable Register enables the
corresponding bit in the Standard Event Status Register. A zero disables
the bit.
OR
To ESB bit in
Statu s Byte
Table 67 Standard Event Status Enable (ESE)
Bit
7
6
5
4
3
2
1
0
Query Syntax
*ESE?
166
(see
page
1208)
128
64
32
16
8
4
PON
URQ
CME
EXE
DDE
QYE
7
6
5
4
3
2
Register
Name
Description
PON
Power On
URQ
User Request
CME
Command Error
EXE
Execution Error
DDE
Device Dependent Error
QYE
Query Error
RQL
Request Control
OPC
Operation Complete
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
2
1
Standard Event
RQL
OPC
*ESR?
Status Register
1
0
Standard Event
*ESE
Status Enable
*ESE?
(Mask) Register
When Set (1 = High = True), Enables:
Event when an OFF to ON transition occurs.
Event when a front-panel key is pressed.
Event when a command error is detected.
Event when an execution error is detected.
Event when a device-dependent error is detected.
Event when a query error is detected.
Event when the device is requesting control. (Not
used.)
Event when an operation is complete.

Advertisement