Sbus<N>:Flexray:trigger:event:type - Agilent Technologies InfiniiVision 4000 X-Series Programmer's Manual

Oscilloscopes
Hide thumbs Also See for InfiniiVision 4000 X-Series:
Table of Contents

Advertisement

:SBUS<n>:FLEXray:TRIGger:EVENt:TYPE
Command Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:TYPE <event>
<event> ::= {WAKeup | TSS | {FES | DTS} | BSS}
Selects the FlexRay event to trigger on. The event setting is only valid
when the FlexRay trigger mode is set to EVENt.
• WAKeup — triggers on Wake- Up event.
• TSS — triggers on Transmission Start Sequence event.
• FES — triggers on either Frame End or Dynamic Trailing Sequence
• DTS — triggers on either Frame End or Dynamic Trailing Sequence
• BSS — triggers on Byte Start Sequence event.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:TYPE?
The :SBUS<n>:FLEXray:TRIGger:EVENt:TYPE? query returns the currently
selected FLEXray event.
Return Format
<event><NL>
<event> ::= {WAK | TSS | {FES | DTS} | BSS}
See Also
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
(see
page
1208)
event.
event.
"Introduction to :TRIGger Commands"
":SBUS<n>:FLEXray:TRIGger:EVENt:AUToset"
":SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID"
":SBUS<n>:FLEXray:TRIGger"
":SBUS<n>:FLEXray:AUTosetup"
":SBUS<n>:FLEXray:SOURce"
on page 935
on page 697
on page 698
on page 695
on page 687
on page 694
28
:SBUS<n> Commands
699

Advertisement

Table of Contents
loading

Table of Contents