29
:SEARch Commands

:SEARch:SERial:USB:PID:SPECial

Command Syntax
:SEARch:SERial:USB:PID:SPECial <pid>
<pid> ::= {PING | PRE | ERR | SPLit}
The :SEARch:SERial:USB:PID:SPECial command specifies the USB special
PID to find.
The SPECial USB search mode can be selected using the
:SEARch:SERial:USB:MODE command.
Query Syntax
:SEARch:SERial:USB:PID:SPECial?
The :SEARch:SERial:USB:PID:SPECial? query returns the specified special
PID.
Return Format
<pid><NL>
<pid> ::= {PING | PRE | ERR | SPL}
See Also
904
(see
page
1208)
":SEARch:SERial:USB:MODE"