Agilent Technologies InfiniiVision 4000 X-Series Programmer's Manual page 163

Oscilloscopes
Hide thumbs Also See for InfiniiVision 4000 X-Series:
Table of Contents

Advertisement

Table 66 Common (*) Commands Summary (continued)
Command
*RCL <value> (see
page
175)
*RST (see
page
176)
*SAV <value> (see
page
179)
*SRE <mask> (see
page
180)
n/a
*TRG (see
page
184)
n/a
*WAI (see
page
186)
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
Query
n/a
n/a
n/a
*SRE? (see
page
181)
*STB? (see
page
182)
n/a
*TST? (see
page
185)
n/a
Common (*) Commands
Options and Query Returns
<value> ::= {0 | 1 | 4 | 5 | 6 |
7 | 8 | 9}
See *RST (Reset) (see
<value> ::= {0 | 1 | 4 | 5 | 6 |
7 | 8 | 9}
<mask> ::= sum of all bits that
are set, 0 to 255; an integer in
NR1 format. <mask> ::= following
values:
Bit Weight Name Enables
--- ------ ---- ----------
7
128
OPER Operation Status Reg
6
64
---- (Not used.)
5
32
ESB
Event Status Bit
4
16
MAV
Message Available
3
8
---- (Not used.)
2
4
MSG
Message
1
2
USR
User
0
1
TRG
Trigger
<value> ::= 0 to 255; an integer
in NR1 format, as shown in the
following:
Bit Weight Name "1" Indicates
--- ------ ---- ---------------
7
128
OPER Operation status
condition occurred.
6
64
RQS/ Instrument is
MSS
requesting service.
5
32
ESB
Enabled event status
condition occurred.
4
16
MAV
Message available.
3
8
---- (Not used.)
2
4
MSG
Message displayed.
1
2
USR
User event
condition occurred.
0
1
TRG
A trigger occurred.
n/a
<result> ::= 0 or non-zero value;
an integer in NR1 format
n/a
5
page
176)
163

Advertisement

Table of Contents
loading