:WGEN<w>:TRACk:FREQuency
Command Syntax
:WGEN<w>:TRACk:FREQuency <on_off>
<w> ::= 1 or 2 in NR1 format
<on_off> ::= {{1 | ON} | {0 | OFF}
The :WGEN<w>:TRACk:FREQuency ON command causes frequency
adjustments to this waveform generator output signal to be tracked by the
other waveform generator output.
Not all waveform shapes can be frequency tracked. When
:WGEN<w>:TRACk or :WGEN<w>:TRACk:FREQuency is enabled, the other
generator's waveform selections (:WGEN<w>:FUNCtion) must be in the
same group as this generator's waveform:
Group 1
SINusoid
RAMP
SINC
CARDiac
GAUSsian
When tracking is enabled, adjustments for tracked settings in the other
waveform generator become unavailable.
Query Syntax
:WGEN<w>:TRACk:FREQuency?
The :WGEN<w>:TRACk:FREQuency? query returns whether frequency
tracking is on or off.
Return Format
<on_off><NL>