Power:harmonics:standard - Agilent Technologies InfiniiVision 4000 X-Series Programmer's Manual

Oscilloscopes
Hide thumbs Also See for InfiniiVision 4000 X-Series:
Table of Contents

Advertisement

25
:POWer Commands

:POWer:HARMonics:STANdard

Command Syntax
:POWer:HARMonics:STANdard <class>
<class> ::= {A | B | C | D}
The :POWer:HARMonics:STANdard command selects the standard to
perform current harmonics compliance testing on.
• A — IEC 61000- 3- 2 Class A — for balanced three- phase equipment,
• B — IEC 61000- 3- 2 Class B — for portable tools.
• C — IEC 61000- 3- 2 Class C — for lighting equipment.
• D — IEC 61000- 3- 2 Class D — for equipment having a specified power
Query Syntax
:POWer:HARMonics:STANdard?
The :POWer:HARMonics:STANdard query returns the currently set IEC
61000- 3- 2 standard.
Return Format
<class><NL>
<class> ::= {A | B | C | D}
See Also
562
(see
page
1208)
household appliances (except equipment identified as Class D), tools
excluding portable tools, dimmers for incandescent lamps, and audio
equipment.
according less than or equal to 600 W, of the following types: personal
computers and personal computer monitors, television receivers.
":POWer:HARMonics:APPLy"
":POWer:HARMonics:DATA"
":POWer:HARMonics:DISPlay"
":POWer:HARMonics:FAILcount"
":POWer:HARMonics:LINE"
":POWer:HARMonics:POWerfactor"
":POWer:HARMonics:RUNCount"
":POWer:HARMonics:STATus"
":POWer:HARMonics:THD"
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide