sflow extended-switch enable

Enable packing information on a switch only.
Syntax
sflow extended-switch enable
To disable packing information, use the no sflow extended-switch [enable]
command.
Parameters
enable
Defaults
Disabled.
Command
CONFIGURATION
Modes
Command
Version 8.3.16.1
History
Usage
The Dell Networking OS version 7.8.1.0 and later enhances the sflow
Information
implementation for real time traffic analysis to provide extended gateway
information in cases where the destination IP addresses are learned by different
routing protocols and for cases where the destination is reachable over ECMP.
Related
show sflow
Commands
sflow polling-interval (Global)
Set the sFlow polling interval at a global level.
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval
command.
Parameters
interval value
Defaults
20 seconds
Command
CONFIGURATION
Modes
Command
Version 8.3.16.1
History
Usage
The polling interval for an interface is the maximum number of seconds between
Information
successive samples of counters sent to the collector. This command changes the
sFlow
Enter the keyword enable to enable global extended
information.
Introduced on the MXL 10/40GbE Switch IO Module.
— displays the sFlow configuration.
Enter the interval value in seconds. The range is from 15 to
86400 seconds. The default is 20 seconds.
Introduced on the MXL 10/40GbE Switch IO Module.