Show Redundancy - Dell MXL 10GbE Reference Manual

Switch i/o module
Table of Contents

Advertisement

---
0
1
2
3
4
5
Dell#reset stack-unit ?
<0-5> Unit number id
Dell#reset stack-unit 0
% Error: Reset of master unit is not allowed.
Dell(standby)#reset stack-unit 3
% Error: Reset of stack units from standby is not allowed.
Dell(standby)#
Dell(standby)#reset stack-unit 1
<00:02:50: %STKUNIT4-S:CP %CHMGR-5-STACKUNIT_RESET: Stack unit
4 being reset
00:02:50: %STKUNIT4-S:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 4
down - reset
00:02:50: %STKUNIT4-S:CP %IFMGR-1-DEL_PORT: Removed port:
TenGig 4/1-48
Dell#rebooting
U-Boot 1.1.4 (June 6 2012 - 00:00:04)
Related
Commands

show redundancy

Display the current redundancy configuration (status of automatic reboot configuration on stack
management unit).
Syntax
show redundancy
Command
Modes
Command
Version 8.3.16.1
History
Example
Dell#show redundancy
-- Stack-unit Status --
------------------------------------------------
-- Stack-unit Redundancy Configuration --
Stacking
Management online
Standby
online
Member
online
Member
online
Member
online
Member
online
reload
— reboots the system.
redundancy
disable-auto-reboot— resets the designated stack member.
EXEC
EXEC Privilege
Introduced on the MXL 10/40GbE Switch IO Module.
Mgmt ID:
Stack-unit ID:
Stack-unit Redundancy Role: Primary
Stack-unit State:
Stack-unit SW Version:
Link to Peer:
Peer Stack-unit:
MXL-10/40GbE
MXL-10/40GbE 9-1-0-853 56
MXL-10/40GbE
MXL-10/40GbE 9-1-0-853 56
MXL-10/40GbE
MXL-10/40GbE 9-1-0-853 56
MXL-10/40GbE
MXL-10/40GbE 9-1-0-853 56
MXL-10/40GbE
MXL-10/40GbE 9-1-0-853 56
MXL-10/40GbE
MXL-10/40GbE 9-1-0-853 56
0
0
Active
E8-3-16-160
Down
not present