Chapter 7, “Link Aggregation Control Protocol Commands” describes the commands to clear counters of all LACP aggregators or a given LACP aggregator. • Chapter 8, “Layer 2 System Commands” describes the commands to configure Layer 2 features. • Chapter 9, “FCoE Configuration Commands”...
Supported hardware and software The following hardware platform is supported in this release: • Dell M8428-k Within this manual, any appearance of the term “Dell FCoE hardware” is referring to: • Dell M8428-k • Dell FCOE10-24 port blade •...
Safety labels are also attached directly to products to warn of these conditions or situations. Notice to the reader This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations. Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: 1.
However, the interface port operands are usually interchangeable, so to simplify the syntax portion of these commands, they have been condensed to {in | ex}tengigabitethernet. This syntax means that the word tengigabitethernet must be preceded by either in or ex, with no spaces. Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Source password []? To copy the source file from a remote machine using SCP: switch#copy scp://user:password@10.10.10.10/file1 file2 To copy the source file from a local switch: switch#copy flash://file1 file2 See Also write erase, copy running-config Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Source password []? Building configuration... To copy the startup configuration file to a remote server through SCP: switch#copy startup-config scp://admin@10.10.10.10/file2 Source password []? Building configuration... See Also write erase, copy running-config Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To delete a file from the Flash: switch#delete file1 % Warning: File will be deleted (from flash:)! Continue?(y/n):y [or] switch#delete flash://file1 % Warning: File will be deleted (from flash:)! Continue?(y/n):y See Also copy startup-config Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
This is the only command that allows you to return to the EXEC mode. Using the exit or quit Guidelines commands from the Privileged EXEC mode ends the session instead of returning to the EXEC mode. Examples To return to the EXEC mode: switch#disable switch> See Also enable, end, exit Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 26
Wed Feb 4 07:08:49 2009 startup_rmon_config -rw-r----- 1276 Wed Feb 4 07:10:30 2009 rmon_config -rw-r----- 1276 Wed Feb 4 07:12:33 2009 rmon_configuration -rw-r----- 1276 Wed Feb 4 10:48:59 2009 starup-config switch(config)# See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To return to the EXEC mode from Privileged EXEC mode, use the disable command. Using the exit Guidelines or quit command from the Privileged EXEC mode ends the session. Examples To enable the Privileged EXEC mode: switch> enable switch# See Also disable Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to return to the Privileged EXEC command mode from any command mode. Usage There are no usage guidelines for this command. Guidelines Examples To return to the Privileged EXEC mode from interface configuration mode: switch(config)#interface intengigabitethernet 0/0 switch(conf-if-te-0/0)#end switch# See Also exit, disable, enable Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To erase the files from the Flash: switch#erase flash %% Warning: Erasing flash filesystem will remove all files in flash://. Continue to erase?(y/n):y switch# See Also dir, delete Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
An exec-timeout setting of 0 (zero) causes the Telnet session to wait indefinitely. Examples To configure the wait interval for the console session: switch(config)#line console 0 switch(conf-line)#exec-timeout 2 30 switch(config)#line vty 0 9 switch(conf-line)#exec-timeout 30 30 See Also show line, line vty, line console Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To exit the Interface configuration mode, and return to the Configuration mode: switch(config)#interface intengigabitethernet 0/0 switch(conf-if-te-0/0)#exit switch(config)#exit See Also end, enable, disable Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To configure the wait interval for the console session: switch>enable switch#configure terminal switch(config)#line console 0 switch(config-line)#exec-timeout 2 30 switch(config-line)#exit See Also show line Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To configure the wait interval for the telnet session to time out after 2 minutes, 30 seconds if there is no response from the user: switch#configure terminal switch(config)#line vty 23 31 switch(conf-line)#exec-timeout 2 30 See Also show line Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines Use no protect-mode enable to disable this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Modes Description Use this command to view the current working directory. Usage There are no usage guidelines for this command. Guidelines Examples To view the current working directory: switch#pwd flash: See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To rename a file in the Flash: switch#rename file1 file2 switch#dir Contents of flash:// -rw-r----- 1276 Wed Feb 4 13:16:00 2009 file2 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Privileged EXEC Mode Modes User Guidelines The scripting support only supports textual configuration files. It does not handle any scripting languages, such as Tcl, Expect, and so on. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no default configurations for this command. Command Privileged EXEC Mode Modes User Guidelines There are no usage guidelines for this command. Example switch#show accounting logs 2009/06/24-03:33:45 (UTC), root/root/10.2.2.47/telnet/CLI/Frisco-34, config; rmon event 15 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display the current date and time based on the switch hardware clock. Usage There are no usage guidelines for this command. Guidelines Examples To display calendar information: switch#show calendar 16:33:30 UTC Tue Feb 14 2009 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To display the time and date from the system clock: switch#show clock 23:45:55.512800 UTC Wed Feb 18 2009 See Also show calendar Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Fan 1 is Ok Fan 2 is Ok Fan 3 is Ok -- Power Supplies PS0 is OK PS1 is faulty -- Unit Environment Status Sensor State Centigrade Fahrenheit ================================================= See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
20 10:0 Idle vty 21 10:0 Idle vty 22 121:1212 switch#show line 0 Status Type Timeout(m/s) Length Idle console 0 10:0 * Active vty 0 10:0 See Also line vty, line console, exec-timeout Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
2009/02/03-00:19:43: %NSM-4-1001: Interface InTenGigabitEthernet 0/4 is online. 2009/02/03-00:20:14: %NSM-4-1002: Interface InTenGigabitEthernet 0/4 is protocol down. 2009/02/03-00:20:14: %NSM-4-1001: Interface InTenGigabitEthernet 0/4 is online. 2009/02/03-00:21:10: %NSM-4-1003: Interface Port-channel 10 is link down See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
BR Min Serial No AAA108454100431 Date Code 081108 Temperature 44 Centigrade Voltage 3246.8 (Volts) Current 0.002 (mAmps) TX Power (uWatts) RX Power (uWatts) (output truncated) See Also show media interface, show media linecard Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max BR Min Serial No AAA108454100431 Date Code 081108 Temperature 44 Centigrade Voltage 3246.8 (Volts) Current 0.002 (mAmps) TX Power (uWatts) RX Power (uWatts) See Also show media, show media linecard Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
BR Max BR Min Serial No AAA108454100431 Date Code 081108 Temperature 44 Centigrade Voltage 3246.8 (Volts) Current 0.002 (mAmps) TX Power (uWatts) RX Power (uWatts) (output truncated) See Also show media interface, show media Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display the current status of protect mode. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
: UP -- Power Supplies -- PS0 is OK PS1 is OK -- Fan Status -- Fan 1 is Ok Fan 2 is Ok Fan 3 is Ok See Also show version, show environment Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Switch Model Name: Dell M8428-k Control Processor: Freescale Semiconductor 8548E with 1016 MB of memory 4MB of boot flash memory. 8 FC Port(s) 24 Ten GigabitEthernet/IEEE 802.3 interface(s) ------------------ show running-config ------------------ switch# See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Displays the line numbers. Idle Displays how long the session has been idle. Location Displays the IP address of the user. User Displays the user name of all users logged in. See Also show line Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Switch Model Name: Dell M8428-k Control Processor: Freescale Semiconductor 8548E with 1016 MB of memory 4MB of boot flash memory. 8 FC Port(s) 24 Ten GigabitEthernet/IEEE 802.3 interface(s) switch# See Also show system Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If 0 (zero), the switch does not pause between screens of output. Guidelines Examples To set the number of lines to display on the screen to 30: switch#terminal length 30 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To enable the display of the RASlog and the debug outputs on a terminal: switch#terminal monitor To disable the display of the RASlog and the debug outputs on a terminal: switch#terminal no monitor See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Privileged EXEC mode Modes Description Use this command to remove a startup configuration. Usage There are no usage guidelines for this command. Guidelines Examples To clear a startup configuration: switch#write erase See Also write memory Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To write configuration data to a file: switch#write memory Overwrite the startup config file (y/n): y Building configuration... See Also write erase Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
VLAN-tagged packets coming into the interface, the FCoE hardware sends out untagged packets to the CNA. These packets may be dropped, disrupting communications. Examples To create a VLAN with ID 56: switch(config)#interface vlan 56 switch-cmsh(conf-if-vl-56)# See Also interface switchport, fcf forward, shutdown Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
1 VLAN Name State Ports (u)-Untagged, (t)-Tagged (c)-Converged ======= ================ ======= =============================== default ACTIVE Te 0/0(t) Te 0/4(t) Te 0/5(t) Te 0/8(t) Te 0/10(t) Te 0/11(c) Po 1(t) Po 63(t) See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Guidelines specified, a specific configured VLAN classifier group is shown. Examples To display the VLAN classifier for group 1: switch#show vlan classifier group 1 vlan classifier group 1 rule 1 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To put an interface in Layer 2 mode: switch(conf-if-te-0/1)#switchport To remove an interface from Layer 2 mode: switch(conf-if-te-0/1)#no switchport See Also show vlan brief, show interface switchport, switchport mode, switchport access, switchport trunk Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no switchport access vlan command to set the PVID to the default VLAN 1. Examples To set the Layer 2 interface PVID to 100: switch(conf-if-te-0/19)#switchport access vlan 100 See Also show vlan brief, show interface switchport, switchport mode, switchport trunk Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
100 To remove the tagged VLAN 100 from the interface: switch(conf-if-te-0/19)#switchport converged allowed vlan remove 100 See Also show vlan brief, show interface switchport, switchport mode, switchport trunk Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To set the mode of the interface to trunk: switch(conf-if-te-0/19)#switchport mode trunk To set the mode of the interface to converged: switch(conf-if-te-0/19)#switchport mode converged See Also show vlan brief, show interface switchport, switchport trunk Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
100 To remove the tagged VLAN 100 from the interface: switch(conf-if-te-0/19)#switchport truck allowed vlan remove 100 See Also show vlan brief, show interface switchport, switchport mode, switchport trunk Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage A VLAN classifier cannot be added to the FCoE VLAN. Guidelines Examples To activate VLAN classifier group 1 for VLAN 5: switch-cmsh(conf-if-te-0/10)#vlan classifier activate group 1 vlan 5 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
VLAN-tagged packets coming into the interface, the FCoE hardware sends out untagged packets to the CNA. These packets may be dropped, disrupting communications. Examples To add rule 1 to VLAN classifier group 1: switch(config)#vlan classifier group 1 add rule 1 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
This classifier group can further be applied on an interface. Examples To create an fcoe VLAN classifier rule: switch(config)#vlan classifier rule 2 proto fcoe encap ethv2 To create a MAC-based VLAN classifier rule: switch(config)#vlan classifier rule 2 mac 0000.0000.0100 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 75
See Also show vlan interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
The clear counters all command does not clear counters for any of the protocol daemon stats like LLDP, LACP, MSTP, and so on. For the Dell M8428-k switch, the slot number is always 0 (zero). Example To clear the statistics for 10 Gbps Ethernet interface 0/1: switch#clear counters interface intengigabitethernet 0/1 To clear the statistics for MAC access list named “test”:...
Page 78
See Also show interfaces Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to specify a string that contains the description of the interface. Use the no description command to remove the description. Usage There are no usage guidelines for this command. Guidelines Examples To set the string describing internal tengigabitethernet interface 0/1: switch(conf-if-te-0/1)#description converged_101 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to create or enter the interface configuration mode to configure an interface. Usage There are no usage guidelines for this command. Guidelines Examples none See Also show interface, interface vlan Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
By default, all 10 Gbps Ethernet interfaces use a default MTU of 2500 bytes. Command Interface configuration mode Modes Description Use this command to specify the MTU on the interface. Usage Creating MTUs under VLAN interfaces is not valid. Guidelines Examples none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Port-channel 13 unassigned Port-channel 14 unassigned down Port-channel 15 unassigned InTenGigabitEthernet 0/0 unassigned InTenGigabitEthernet 0/1 unassigned down InTenGigabitEthernet 0/2 unassigned InTenGigabitEthernet 0/3 unassigned InTenGigabitEthernet 0/4 unassigned down InTenGigabitEthernet 0/5 unassigned down Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 85
ExTenGigabitEthernet 0/20 unassigned ExTenGigabitEthernet 0/21 unassigned ExTenGigabitEthernet 0/22 unassigned ExTenGigabitEthernet 0/23 unassigned Vlan 1 unassigned administratively down down Vlan 100 unassigned administratively down down Vlan 200 unassigned administratively down down See Also show interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to disable an interface. Usage There are no usage guidelines for this command. Guidelines Examples To disable an interface: switch(conf-if-te-0/1)#shutdown To enable an interface: switch(conf-if-te-0/1)#no shutdown See Also interface, show ip interface, show interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
The speed command is available only for intengigabitethernet ports. It is not valid for extengigabitethernet ports. The speed for extengigabitethernet ports is fixed at 10000 and cannot be changed). Example switch(conf-if-int-0/1)#speed 10000 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to enable tracking. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use the no track version to disable this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to enable tracking on an interface. Defaults There are no default configurations for this command. Command Interface configuration mode Modes User Guidelines Use the no track interface version to disable this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to define a static ARP connection between an IP address to a local data link address. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to configure the ARP timeout. Defaults Default value is 240 minutes (four hours.) Command Global configuration mode Modes User Guidelines Use no arp-ageing-timeout to disable this function. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear the ARP statistics cache on the host. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear the FIB and hardware. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also show ip fib Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear all or some of the IP routes on the switch. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear the IP traffic statistics. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display the ARP traffic, for all interfaces or a specific interface. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
When the secondary parameter is specified, this command adds a new IP address to the interface. The secondary address cannot be configured in the absence of a primary IP. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the command no ip mtu to disable the MTU. The valid range is from 576 through 9018. The default IP MTU size is 1500 bytes. The default link MTU size is 2500 bytes. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to enable proxy ARP. Defaults By default, proxy ARP is disabled. Command Privileged EXEC mode Modes User Guidelines Use no ip proxy-arp to disable proxy ARP. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to configure static IP routes. Defaults There are no default configurations for this command. Command Global configuration mode. Modes User Guidelines Use no ip route to remove the static IP route. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to trap IP fragmentations or TTL violations to the CPU. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use no ip trap-to-cpu to disable the trap. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display the contents of the ARP cache. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also show ip forwarding, show ip forwarding, show ip fib Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also show ip forwarding, show ip forwarding, show interfaces, clear ip fib Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also show ip interface, show ip fib, show interfaces Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also show ip forwarding, show ip fib, show interfaces Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
- IS-IS inter area, * - candidate default, U - per-user static route o - ODR, P - periodic downloaded static route Gateway of last resort is 10.32.144.1 to network 0.0.0.0 10.0.0.0/8 is variably subnetted, 2 subnets, 2 masks 10.0.0.0/8 [1/0] via 10.32.144.1 10.32.144.0/20 is directly connected, GigabitEthernet4/47 0.0.0.0/0 [1/0] via 10.32.144.1...
There are no user guidelines for this command. Example Example output of this command: switch>show ip route summary Route Source Networks Subnets Overhead Memory (bytes) connected static internal 1180 Total 1660 See Also show ip route Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
FCoE priority, and Priority Flow Control (PFC) pause. Use the no advertise dcbx-fcoe-app-tlv command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples none See Also advertise dot1-tlv, advertise dot3-tlv, advertise optional-tlv Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to advertise to any attached device the FCoE status of the logical link. Use the no advertise dcbx-fcoe-logical-link-tlv command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples none See Also advertise dcbx-fcoe-app-tlv, advertise dcbx fcoe-app-tlv Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Length, Values (TLVs). Use the no advertise dcbx-tlv command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples none See Also advertise dot1-tlv, advertise dot3-tlv, advertise optional-tlv Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Length, Value (TLV). Use the no advertise dot1-tlv command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples none See Also advertise dot3-tlv, advertise dcbx-tlv, advertise optional-tlv Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Length, Value (TLV). Use the no advertise dot3-tlv command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples none See Also advertise dot1-tlv, advertise dcbx-tlv, advertise optional-tlv Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display the following optional TLVs. Use the no advertise optional-tlv command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If the interface operand is not specified, this command clears the LLDP neighbor information Guidelines received on all the interfaces. Examples To clear the LLDP information for all interfaces: switch#clear lldp neighbors See Also show lldp neighbors Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If the interface operand is not specified, this command clears all the LLDP statistics on all Guidelines interfaces. Examples To clear all the LLDP statistics for all interfaces: switch#clear lldp statistics See Also show lldp statistics Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To enable debugging of LLDP for both received and transmitted packets on 10 Gbps Ethernet Examples interface 0/1: switch#debug lldp packet interface intengigabitethernet 0/1 both switch#show debug lldp LLDP debugging status: Interface te0/1 : Transmit Receive See Also show debug lldp Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to specify a string that contains the description of the LLDP. Use the no description command to remove the description. Usage There are no usage guidelines for this command. Guidelines Examples To set the strings describing LLDP: switch(conf-lldp)#description Dell-LLDP See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To set the time interval to 10 seconds between the transmissions: switch#configure terminal switch (config) #protocol lldp switch(conf-lldp)#hello 10 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to specify which version of the DCBX protocol to use. Usage There are no usage guidelines for this command. Guidelines Examples To specify which DCBX version to use: switch(conf-if-te-0/1)#lldp dcbx-version cee See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to disable LLDP on the interface. Use the no lldp disable command to enable LLDP on the interface. Usage There are no usage guidelines for this command. Guidelines Examples To disable LLDP on the interface. switch(conf-if-te-0/1)#lldp disable See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Operands value Specifies the bitmap value. The range of valid values is 0 to 15. Defaults The default value is 8. Command Interface configuration mode Modes Description Use this command to set the priorities on which FCoE traffic will be allowed. The no lldp fcoe-priority-bits command returns to the default setting.
Only one LLDP profile can exist at any time for a particular interface. When this command is not present, the parameters defined in the global LLDP configuration are used. Examples To apply an LLDP profile on an interface: switch(conf-if-te-0/1)#lldp profile test See Also protocol lldp Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to set the LLDP mode on the switch. Use the no mode command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples To enable only the transmit mode: switch(conf-lldp)#mode tx See Also show lldp Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no multiplier command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples To set the number of consecutive misses: switch(conf-lldp)#multiplier 2 See Also hello Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Up to 64 profiles can be created. Examples To create a profile named test: switch(conf-lldp)#profile test To delete a profile named test: switch(conf-lldp)#no profile test See Also lldp profile Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no protocol lldp command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples To clear all LLDP configurations: switch(config)#no protocol lldp See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To display the LLDP debugging status on the switch: switch#show debug lldp LLDP debugging status: Interface te0/0 : Transmit Receive Detail See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
1 seconds DCBX Version : Auto-Sense : Transmit TLVs: Chassis ID Port ID IEEE DCBX DCBX FCoE App DCBX FCoE Logical Link Link Prim Brocade Link DCBX FCoE Priority Bits: 0x8 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If you do not use the interface operand, only the mandatory TLVs are displayed. Guidelines Examples To display detailed LLDP neighbor information on a specific interface: switch#show lldp neighbors interface intengigabitethernet 0/8 detail Neighbors for Interface Te 0/8 MANDATORY TLVs ===============...
Page 133
FCoE LLS OperVersion: 0 MaxVersion: 0 EN: 1 Will: 0 Err: 0 Logic Link Status: Down LAN LLS OperVersion: 0 MaxVersion: 0 EN: 1 Will: 0 Err: 0 Logic Link Status: Up switch# See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If you do not specify the interface tengigabitethernet operand, this command displays the LLDP Guidelines statistics for all interfaces. Examples To display LLDP statistics on the specified interface: switch#show lldp statistics interface intengigabitethernet 0/8 LLDP Interface statistics for Te 0/8 Frames transmitted: 555 Frames Aged out: Frames Discarded:...
LLDP system description. Usage There are no usage guidelines for this command. Guidelines Examples To set the global system description specific to LLDP: switch(conf-lldp)#system-description Dell See Also system-name Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to set the global system name specific to LLDP. Usage There are no usage guidelines for this command. Guidelines Examples To specify a system name for the LLDP: switch(conf-lldp)#system-name Dell See Also system-description Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
A maximum of four links can become part of a single aggregation group when the type is set to dell and they must be on the same port-channel. • Links 0-7 belong to port-channel 1; links 8-15 belong to port-channel 2, and links 16-23 belong to port-channel 3. •...
Page 138
4 mode active See Also interface port-channel Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear the LACP counters per specified channel-group. Usage There are no default configurations for this command. Guidelines Examples To clear the LACP counters for a specific port-channel: switch#clear lacp 10 counters See Also show lacp counters Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear the LACP counters for all port-channels. Usage There are no default configurations for this command. Guidelines Examples To clear the counters for all port-channels: switch#clear lacp counters See Also show lacp Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to enable debugging for Link Aggregation Control Protocol (LACP). Use the no debug command to disable debugging. Usage To display debug outputs on a specific cmsh session, use the terminal monitor command. Guidelines Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 142
To enable debugging of LACP PDUs for transmitted and received packets on all interfaces: switch#debug lacp pdu tx all switch#debug lacp pdu rx all switch#show debug lacp LACP rx debugging is on LACP tx debugging is on See Also show debug lacp Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To set the LACP system-priority to 68: switch(config)#lacp system-priority 68 To clear the configured LACP system-priority: switch(config)#no lacp system-priority See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Interface configuration mode Modes Description Use this command to set the short timeout value for Dell trunks or to set the long timeout value for standard trunks. Use the no lacp timeout command to return to the default value. Usage...
DOWN even though it has operationally UP members. Defaults The default number of links is 1. Command Interface configuration mode Modes User Guidelines Use no minimum-links to disable this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
% Traffic statistics Port LACPDUs Marker Pckt err Sent Recv Sent Recv Sent Recv % Aggregator Po 10 1000000 Te 0/1 Te 0/2 Te 0/3 Te 0/4 switch# See Also clear lacp counters Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
The first two bytes are the system priority, and the last six bytes are the globally administered individual MAC addresses associated with the system. Examples To display the local system ID: switch#show lacp sys-id % System M8428-k,00-05-1e-76-1a-a6 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to set the aging time or to add static addresses to the MAC address table. Usage The vlan keyword is mandatory because the switch only supports independent VLAN learning (IVL). Guidelines Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 150
To add the static address 0011.2222.3333 to the MAC address table with a packet received on VLAN 100: switch(config)#mac-address-table static 0011.2222.3333 forward intengigabitethernet 0/1 vlan 100 To set the aging time to 10 minutes: switch(config)#mac-address-table aging-time 600 See Also show mac address-table static Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Specifies a valid slot number. port Specifies a valid port number. static Displays the static MAC addresses. vlan vlan_id Specifies the VLAN number. The range of valid values is 1-3583. Defaults No static addresses are configured. Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 152
State Ports 0011.2222.5555 Dynamic Inactive Te 0/1 0011.2222.6666 Dynamic Inactive Te 0/1 Total MAC addresses See Also show mac address-table dynamic, show mac address-table static, show mac address-table linecard, show mac address-table count Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use no fcoe-map to revert to the default values for the map. Examples none See Also fcoeport Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If the interface is configured as fcoeport, the fcoeport configuration will take precedence over the switchport mode. If the switchport mode is configured as access or trunk it will be ignored. Example Enter interface mode, then apply the FCoE map. switch(config)#interface extengigabitethernet 0/20 switch(conf-if-ext-0/20)#fcoeport See Also fcoe-map Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
FCoE VLAN. Usage There are no usage guidelines for this command. Guidelines Example You must first enter FCoE map mode, then configure the VLAN. switch(config)#fcoe-map default switch(conf-fcoe-map)#fcoe-vlan 5 See Also fcoe-map, fcoeport Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display the current FCoE map information. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To clear counters for the configured MAC access list named test on all interfaces on which this ACL is applied: switch#clear counters access-list mac test See Also show mac access-list, show statistics access-list Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To create a rule in a MAC extended ACL to drop IPv4 traffic from the source MAC address to the destination MAC address and to enable the counting 0022.3333.4444 0022.3333.5555 of packets: switch(conf-macl-ext)#deny 0022.3333.4444 0022.3333.5555 ipv4 count To delete a rule from a MAC extended ACL: Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To create a rule in a MAC standard ACL to drop traffic from the source MAC address and to enable the counting of packets: 0022.3333.4444 switch(conf-macl-std)#deny 0022.3333.4444 count To delete a rule from a MAC standard ACL: switch(conf-macl-std)#no deny 0022.3333.4444 See Also mac-access-list extended, permit Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Example To create a MAC extended ACL named mac1: switch(config)#mac access-list extended mac1 switch(conf-macl-ext)# To delete a MAC extended ACL named mac1: switch(config)#no mac access-list extended mac1 See Also deny, permit, show access-lists Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Example To create a MAC standard ACL named mac1: switch(config)#mac access-list standard mac1 switch(conf-macl-std)# To delete a MAC standard ACL named mac1: switch(config)#no mac access-list standard mac1 See Also deny, permit, show access-lists Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To apply a MAC ACL named macacl2 on an interface: switch(conf-if)#mac access-group macacl2 in To remove a MAC ACL named macacl2 from an interface: switch(conf-if)#no mac access-group macacl2 See Also mac access-list standard, mac access-list extended, show access-lists Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To create a rule in a MAC extended ACL to permit IPv4 traffic from the source MAC address to the destination MAC address and to enable the counting of 0022.3333.4444 0022.3333.5555 packets: switch(conf-macl-ext)#permit 0022.3333.4444 0022.3333.5555 ipv4 count Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 165
(extended ACLs) To delete a filter rule in a MAC extended ACL: switch(conf-macl-ext)#no permit 0022.3333.4444 0022.3333.5555 ipv4 See Also mac-access-list extended, mac-access-list standard, no seq Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To create a rule in a MAC standard ACL to permit traffic from the source MAC address and to enable the counting of packets: 0022.3333.4444 switch(conf-macl-std)#permit 0022.3333.4444 count To delete a rule from a MAC standard ACL: switch(conf-macl-std)#no permit 0022.3333.4444 See Also mac-access-list extended, no seq Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
The first set of {any | host MAC_ACL | MAC_ACL} parameters is specific to the source MAC Guidelines address. The second set of {any | host MAC_ACL | MAC_ACL} parameters is specific to the destination MAC address. Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 169
0022.3333.5555 packets: switch(conf-macl-ext)#seq 100 deny 0022.3333.4444 0022.3333.5555 ipv4 count switch(conf-macl-ext)#seq 1000 permit 0022.3333.4444 0022.3333.5555 ipv4 count To delete a rule from a MAC extended ACL: switch(conf-macl-ext)#no seq 100 See Also deny, permit, resequence Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
0022.3333.4444 switch(conf-macl-std)#seq 100 deny 0022.3333.4444 count switch(conf-macl-std)#seq 1000 permit 0022.3333.4444 count To delete a filter rule in a MAC standard ACL: switch(conf-macl-std)#no seq 100 See Also deny, permit, resequence Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To display the current MAC ACL mapping for 10 Gbps Ethernet interface 0/7 where there is no ACL applied: switch#show mac access-group interface intengigabitethernet 0/7 Interface Te 0/7 Inbound access-list is not set See Also show running-config, show statistics Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If the rule is not written into the hardware the output displays as shown below: seq 8 permit 00c0.e000.0080 count (unwritten) If the rule is written into the hardware, but the counters are not enabled for that rule, the output displays as shown below: seq 9 permit 00c0.e000.0090 count (uncounted)
Examples To enable Cisco interoperability on a switch: switch#configure terminal switch(config)#protocol spanning-tree mstp switch(conf-mstp)#cisco-interoperability enable To disable Cisco interoperability on a switch: switch#configure terminal switch(config)#protocol spanning-tree mstp switch(conf-mstp)#cisco-interoperability disable See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To clear spanning-tree counters for a 10 Gbps Ethernet interface: switch#clear spanning-tree counter interface intengigabitethernet 0/1 To clear spanning-tree counters for port-channel 23: switch#clear spanning-tree counter interface port-channel 23 See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
0/1 switch#show debug spanning-tree MSTP debugging status: Spanning-tree rx debugging is off Te 0/1 rx is on Spanning-tree tx debugging is off Te 0/1 tx is on Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 177
See Also show debug spanning-tree, show debug Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
This command allows you to enable the interface from the disabled state. Examples To bring the interface out of the disabled state: switch(conf-rstp)#error-disable-timeout enable See Also error-disable-timeout interval Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to set the interface to time out when an error occurs. Usage There are no usage guidelines for this command. Guidelines Examples To set the timeout value to 10 seconds: switch(conf-rstp)#error-disable-timeout interval 10 See Also error-disable-timeout enable Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
When you change the spanning-tree forward-delay time, it affects all spanning-tree instances. Guidelines When configuring the forward-delay, the following relationship should be kept: 2*(forward-delay - 1)>=max-age>=2*(hello-time + 1) Examples To configure the forward-delay time to 18 seconds: switch(conf-mstp)#forward-delay 18 See Also hello-time, max age Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
When configuring the hello-time, the max-age setting must be greater than the hello-time setting. Guidelines The following relationship should be kept: 2*(forward-delay - 1)>=max-age>=2*(hello-time + 1) Examples To configure spanning-tree bridge hello time to 5 seconds: switch(conf-stp)#hello-time 5 See Also forward-delay, max-age Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
VLAN instance mapping is removed from the configuration if the underlying VLANs are deleted. Examples To map a VLAN to an MTSP instance: switch(conf-mstp)#instance 1 vlan 2, 3 switch(conf-mstp)#instance 2 vlan 4-6 switch(conf-mstp)#instance 1 priority 4096 See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
When configuring the maximum age, the max-age setting must be greater than the hello-time Guidelines setting. The following relationship should be kept: 2*(forward-delay - 1)>=max-age>=2*(hello-time + 1) Examples To configure the maximum-age to 10 seconds: switch(conf-rstp)#max-age 10 See Also hello-time, forward delay Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
When you change the number of hops, it affects all spanning-tree instances. Examples To set the number of maximum hops to 25 for all MSTPs: switch(config)#protocol spanning-tree mstp switch(conf-mstp)#max-hops 25 See Also show spanning-tree mst Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To set the behavior for the path-cost to custom: switch(conf-mstp)#port-channel path-cost custom To set the behavior for the path-cost to standard: switch(conf-mstp)#port-channel path-cost standard See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Packet drops or packet flooding may occur if you do not enable xSTP on all devices connected on both sides of parallel links. Examples To enable the Spanning Tree Protocol: switch(config)#protocol spanning-tree stp See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
The region-name string has a maximum length of 32 characters and is case-sensitive. Guidelines Examples To assign a name to an MSTP region named dell1: switch(config)#protocol spanning-tree mstp switch(conf-mstp)#region dell1 See Also revision, show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To set the configuration revision to 1: switch(config)#protocol spanning-tree mstp switch(conf-mstp)#revision 1 See Also region, show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Cost Prio Link-type Boundary Edge ------------------------------------------------------------------------- Te 0/0 2000 Te 0/1 2000 Te 0/2 RTPT 2000 Te 0/3 2000 Te 0/8 2000 Te 0/19 2000 Te 0/20 2000 See Also show spanning-tree interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
------------------------------------------------------------------------- Te 0/0 2000 Te 0/1 2000 Te 0/2 RTPT 2000 Te 0/3 2000 Te 0/8 2000 Te 0/19 2000 Te 0/20 2000 See Also show spanning-tree mst interface, show spanning-tree mst instance Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 195
Version Multiple Spanning Tree Protocol - Received None - Send MSTP Edgeport: off; AutoEdge: no; AdminEdge: no; EdgeDelay: 3 sec Configured Root guard: off; Operational Root guard: off Boundary: yes Bpdu-guard: off Bpdu-filter: off Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 196
Link-type: point-to-point Received BPDUs: 0; Sent BPDUs: 0 MSTI details. ============== See Also show spanning-tree mst interface, show spanning-tree mst instance Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Configured Root guard: off; Operational Root guard: off Boundary: yes Bpdu-guard: off Bpdu-filter: off Link-type: point-to-point Received BPDUs: 0; Sent BPDUs: 0 Instance Role Cost Prio VLANs ----------------------------------------------------------------------- 2000 See Also show spanning-tree brief, show spanning-tree mst brief Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to disable the MSTP, RSTP, or STP protocol globally. Usage This command has no usage guidelines. Guidelines Examples To disable STP globally: switch(config)#protocol spanning-tree rstp switch(conf-rstp)#shutdown To enable STP globally: switch(config)#protocol spanning-tree rstp switch(conf-rstp)#no shutdown See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to automatically identify the edge port. Usage The port can become an edge port if no Bridge Protocol Data Unit (BPDU) is received. Guidelines Examples To enable automatic edge detection: switch(conf-if-te-0/1)#spanning-tree autoedge See Also protocol spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to configure the path cost for spanning-tree calculations. Usage Lower path cost indicates a greater chance of becoming root. Guidelines Examples To set the port cost to 128: switch(conf-if-te-0/1)#spanning-tree cost 128 See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To set the edgeport BPDU filter for the port: switch(conf-if-te-0/1)#spanning-tree edgeport switch(conf-if-te-0/1)#spanning-tree edgeport bpdu-filter To guard the port against reception of BPDUs: switch(conf-if-te-0/1)#spanning-tree edgeport switch(conf-if-te-0/1)#spanning-tree edgeport bpdu-guard See Also spanning-tree portfast bpdu-guard, spanning-tree autoedge Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
If the guard root enabled port receives a superior Bridge Protocol Data Unit (BPDU), it goes to a discarding state. Examples To enable guard root: switch(conf-if-te-0/1)#spanning-tree guard root See Also spanning-tree cost Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Changing the hello-time affects all spanning-tree instances. The max-age setting must be greater Guidelines than the hello-time setting. Examples To set the hello time to 5 seconds: switch(conf-if-te-0/1)#spanning-tree hello-time 5 See Also forward-delay, max-age, show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command for MSTP-specific configurations. Guidelines Examples To set restrictions for the port of MSTP instance 1 with the cost of 40000: switch(conf-if-te-0/1)#spanning-tree instance 1 cost 40000 See Also instance, show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to specify a link type for the Spanning Tree Protocol. Usage This command overrides the default setting of the link type. Guidelines Examples To specify the link type as shared: switch(conf-if-te-0/0)#spanning-tree link-type shared See Also spanning-tree link-type shared, no spanning-tree link-type Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To set the Port Fast BPDU filter for the port: switch(conf-if-te-0/1)#spanning-tree portfast bpdu-filter To guard the port against the reception of BPDUs: switch(conf-if-te-0/1)#spanning-tree portfast bpdu-guard See Also spanning-tree portfast bpdu-guard, spanning-tree autoedge Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To configure the port priority to 16: switch(conf-if-te-0/1)#spanning-tree priority 16 See Also spanning-tree cost, show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To configure the port from becoming a root port: switch(conf-if-te-0/1)#spanning-tree restricted-role See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to restrict the topology change notification Bridge Protocol Data Units (BPDUs) sent on the port. Usage There are no usage guidelines for this command. Guidelines Examples To restrict the TCN on a specific interface: switch(conf-if-te-0/1)#spanning-tree restricted-tcn See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To disable spanning tree on a specific interface: switch(config)#interface intengigabitethernet 0/1 switch(conf-if-te-0/1)#spanning-tree shutdown To enable spanning tree on VLAN 1002: switch(config)#interface vlan 1002 switch(conf-if-vl-1002)#no spanning-tree shutdown See Also protocol spanning-tree Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
MAC address flushing. Usage There are no usage guidelines for this command. Guidelines Examples To disable the MAC address flushing upon receiving any topology change notification: switch(config)#no spanning-tree tc-flush-standard See Also show spanning-tree brief Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To change the number of BPDUs transmitted to 3 seconds: switch(conf-mstp)#transmit-holdcount 3 See Also show spanning-tree mst detail Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To clear information for all groups in the IGMP protocol: switch#clear ip igmp group Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 216
See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear all IGMP group information in the IGMP database. Usage There are no usage guidelines for this command. Guidelines Examples To clear information for all groups in the IGMP protocol: switch#clear ip igmp groups See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Displays all of the IGMP packets received and sent, and IGMP-host related events. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
The query interval is the amount of time in seconds between IGMP query messages sent by the switch. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage This command performs IGMP snooping at the interface level. Guidelines Examples To enable igmp globally: switch(config)# ip igmp snooping enable See Also show ip igmp snooping, ip igmp snooping enable (VLAN version) Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To enable igmp for a specific VLAN interface, enter Interface VLAN mode and execute the following command: switch(conf-if-vl-1)#ip igmp snooping enable See Also show ip igmp snooping, ip igmp snooping enable (global version) Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Defaults This mode is disabled by default. Command Global Configuration mode Modes User Guidelines Use no ip igmp snooping fast-leave to disable this function. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no ip igmp snooping mrouter version of this command to return to the default setting. Guidelines Examples To configure a VLAN port member to be a multicast router interface. switch#ip igmp snooping mrouter interface intengigabitethernet 0/1 See Also show ip igmp snooping mrouter Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
This command sets the timeout range for when multicast router ports are automatically learned. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use no ip igmp snooping querier enable to disable this command. Guidelines Examples To enable the IGMP snooping querier feature: switch(conf-if-vl-1)#ip igmp snooping querier enable See Also show ip igmp interface, show ip igmp snooping interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
IGMP cache and mroute table. Defaults There are no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
This command displays the IGMP packets received and transmitted. Defaults There are no defaults for this command. Command Privileged EXEC mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display the IGMP database, including configured entries for either all groups on all interfaces, or all groups on specific interfaces, or specific groups on specific interfaces. Usage There are no usage guidelines for this command. Guidelines Examples none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
IGMP protocol module. Usage There are no usage guidelines for this command. Guidelines Examples To display information the IGMP snooping information for VLAN 5: switch#show ip igmp snooping interface vlan 5 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Defaults There are no defaults for this command. Command Privileged EXEC mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage You can only specify one sFlow collector. Guidelines Examples To identify the sFlow collectors for the IP address 192.10.138.176 to which sFlow datagrams are forwarded: switch(conf-if-te-0/1)#sFlow collector 192.10.138.176 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no sflow enable command to disable sFlow globally. Usage This command is supported on physical ports and Link Aggregation Group (LAG) ports. Guidelines Examples To enable sFlow globally: switch(config)#sflow enable See Also sflow enable interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
This command is supported on physical ports and Link Aggregation Groups (LAG) ports. After a Guidelines physical port is a member of a LAG, it inherits the sFlow configuration from the LAG port. Examples To enable sFlow on an interface: switch(conf-if-te-0/1)#sflow enable interface See Also sflow enable Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no sflow polling interval interval command to return to the default value. Usage There are no usage guidelines for this command. Guidelines Examples To set the polling interval to 135 seconds: switch(config)#sFlow polling interval 135 See Also sflow polling interval (interface version) Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no sflow polling interval interval command to return to the default value. Usage There are no usage guidelines for this command. Guidelines Examples To set the polling interval to 135 seconds: switch(conf-if-te-0/1)#sFlow polling interval 135 See Also sflow polling interval (global version) Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the no sflow sample-rate command to return to the default sampling rate. Examples To change the sampling rate to 4096: switch(config)#sFlow sample-rate 4096 See Also sflow sample-rate (interface version) Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Select one of these two numbers and re-enter the command. Use the no sflow sample-rate command to return to the default setting. Examples To change the sampling rate to 4096: switch(conf-if-te-0/1)#sFlow sample-rate 4096 See Also sflow sample-rate (global version) Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to specify a string that contains the description of the Port Mirroring session. Use the no description command to remove the description string. Example To set the string describing monitor session 1: sw0(config)#monitor session 1 sw0(config-mon-sess-1)#description server group 1 switch-cmsh See Also monitor session Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
An internal external 10 Gbps Ethernet port can be used as the source port. Only external 10 Gbps Guidelines Ethernet ports can be used as the destination port. Examples To enable session 40 for monitoring traffic: switch(config)#monitor session 40 source intengigabitethernet 0/1 destination extengigabitethernet 0/15 direction both Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to display monitoring information for all Port Mirroring sessions, or for a single session. Usage There are no usage guidelines for this command. Guidelines Examples To display monitoring information for all Port Mirroring sessions: switch#show monitor See Also monitor session Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to set alarm conditions. Use the no rmon alarm command to disable the alarm conditions. Usage There are no usage guidelines for this command. Guidelines Examples To set alarm conditions: Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 248
100 1.3.6.1.2.1.16.1.1.1.5.65535 interval 5 absolute rising-threshold 10000 event 100 falling-threshold 1000 event 101 owner admin See Also rmon event, show rmon Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To collect RMON statistics for the owner admin on 10 Gbps Ethernet interface 0/1: switch(config)#interface intengigabitethernet 0/1 switch(conf-if-te-0/1)#rmon collection history 5 See Also show rmon history Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To collect RMON statistics for the owner admin on 10 Gbps Ethernet interface 0/1: switch(config)#interface intengigabitethernet 0/1 switch(conf-if-te-0/1)#rmon collection stats 2 owner admin See Also show rmon statistics Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
RMON alarm number. Use the no rmon event command to remove the event configuration. Usage There are no usage guidelines for this command. Guidelines Examples To configure an RMON event: switch(config)#rmon event 2 log description “My Errorstoday” owner gjack See Also show rmon events Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 253
To display the RMON events: switch#show rmon events event Index = 4 Description "My Description" Event type Log & SnmpTrap Event community name admin Last Time Sent = 00:00:00 Owner admin See Also rmon alarm, rmon event Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use the statistics option to display the detailed history. Example To display the RMON history: switch#show rmon history RMON history control entry 1 interface: ifIndex.1745682445 InTengigabitEthernet 0/13 buckets requested: 20 buckets granted: 20 sampling interval: 10 Owner: jsmith See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To apply the CEE map on an interface: switch(conf-if-te-0/1)#cee default Because the switch does not allow applying a CEE map that does not exist, the following error displays: switch(conf-if-te-0/1)#cee test % Error: Map does not exist See Also cee-map Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
CoS: --------------------------------------------- PGID: FCoE CoS: None Enabled on the following interfaces Usage Use no cee-map to revert to the default values for the map. Guidelines Examples none See Also cee, priority-group-table, priority-table, fcoe-map Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To define the CEE map and configure the bandwidth with the Priority Group, use the values in Table TABLE 3 Bandwidth allocation to user priority groups PGID Description switch(config)#cee-map test switch(conf-ceemap)#priority-group-table 0 weight 50 pfc switch(conf-ceemap)#priority-group-table 1 weight 50 See Also cee-map, priority-table, show qos Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
PGID (PGID 15.0 to PGID 15.7) is allowed. Examples To define a CEE map of the incoming Priority-to-Priority Groups, use the values in Table TABLE 4 Mapping of incoming Priority-to-Priority Groups Priority PGID Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 259
TABLE 4 Mapping of incoming Priority-to-Priority Groups Priority PGID 15.0 switch(config)#ceemap test switch(conf-ceemap)#priority-table 1 1 0 1 1 1 1 15.0 See Also cee, cee-map, priority-group-table Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Examples To set the interface CoS value to 2: switch(conf-if-te-0/2)#qos cos 2 To return the interface CoS value to the default: switch(conf-if-te-0/2)#no qos cos See Also show qos, qos map, qos trust Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To activate the CoS-to-CoS mutation QoS map on the interface: switch(conf-if-te-0/1)#qos cos-mutation test To remove the CoS-to-CoS mutation QoS map on the interface: switch(conf-if-te-0/1)#no qos cos-mutation See Also qos map cos-mutation, show qos maps Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
This command is not available when the interface is in the CEE Provisioning mode. Guidelines Examples To apply a CoS-to-Traffic Class QoS map to an interface: switch(conf-if-te-0/1)#qos cos-traffic-class test See Also qos map cos-traffic-class, qos trust, qos cos-mutation, show qos maps Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
CoS 4; all other CoS values go through unchanged: switch(config)#qos map cos-mutation test 0 1 2 3 5 4 6 7 switch(config)#interface intengigabitethernet 0/1 switch(conf-if-te-0/1)#qos cos-mutation test To delete a CoS-to-CoS mutation QoS map: switch(config)#no qos map cos-mutation test Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 264
See Also qos cos-mutation, show qos maps Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To create a CoS-to-Traffic Class QoS map to map CoS 0 to Traffic Class 1 and CoS 1 to Traffic Class switch(config)#qos map cos-traffic-class test 1 0 2 3 4 5 6 7 To delete a CoS-to-Traffic Class QoS map: switch(config)#no qos map cos-traffic-class test See Also qos trust, qos map cos-mutation Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
(DWRR). This multicast Traffic Class packet expansion scheduler policy is applied uniformly across the entire system. Use the no qos queue multicast scheduler command to return the multicast Traffic Class packet expansion scheduler to the default value. Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Page 267
10 20 30 40 To return the system to the default multicast Traffic Class packet expansion scheduler policy: switch(config)#no qos queue multicast scheduler See Also qos rcv-queue multicast Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Strict Priority Traffic Classes. The sum of all weight values must equal 100 percent. The weight0 value is only valid when the strict priority number is less than 8. The range of valid values is 0-100 percent.
Page 269
100 percent. The weight0 value is only valid when the strict priority number is less than 1. The range of valid values is 0-100 percent. Defaults The default strict priority value is 8. There is no default value for each weight value. Command Global configuration mode Modes Description Use this command to configure the Traffic Class packet scheduler policy.
To lower the maximum multicast packet expansion rate to 10000pkt/s: switch(config)#qos rcv-queue multicast rate-limit 10000 To return the system to the default multicast packet expansion rate limit values: switch(config)#no qos rcv-queue multicast rate-limit See Also qos rcv-queue multicast Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
1000 1000 1000 1000 1000 1000 1000 1000 To return the system to the default multicast packet expansion Tail Drop Threshold value: switch(config)#no qos rcv-queue multicast threshold See Also qos rcv-queue multicast Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
When a CEE map is applied, the switch does not allow the qos trust cos command and displays the following error: switch(conf-if-te-0/1)#cee demo switch(conf-if-te-0/1)#qos trust cos % Error: QoS is not in non-CEE Provisioning mode See Also qos cos, show qos Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
CEE maps. For each CEE map, the configuration state is displayed with a list of all of the Layer 2 interfaces bound to the CEE map. Usage Fabric OS v6.3.1_cee only allows the CEE map name “default.” Guidelines Examples none See Also cee, cee-map Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
CoS-to-CoS Mutation map 'test' In-CoS: -------------------------------- Out-CoS: Enabled on the following interfaces: Te 0/5 CoS-to-Traffic Class map 'test' Out-CoS: ------------------------------------- TrafficClass: Enabled on the following interfaces: Te 0/5 See Also qos maps, show qos interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
For a stand-alone switch, all ASICs are considered as slot number zero (0). Guidelines Examples To display the queueing information: switch#show qos rcv-queue multicast intengigabitethernet 0/2 Dropped Counts Linecard/Portset TC 0 TC 1 TC 2 TC 3 ----------------------------------------------------------------------------- See Also show qos rcv-queue interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear all accumulated port authentication statistics on all ports. Usage There are no usage guidelines for this command. Guidelines Examples To clear dot1x statistics: switch>clear dot1x statistics See Also clear dot1x statistics interface Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to clear all of the dot1x statistics for a specific interface port. Usage There are no usage guidelines for this command. Guidelines Examples To clear dot1x statistics on a port: switch#clear dot1x statistics interface extengigabitethernet 0/16 See Also clear dot1x statistics Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
802.1X management. Usage There are no usage guidelines for this command. Guidelines Examples To enable dot1x on a port: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x authentication See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to globally enable 802.1X authentication. Use the no dot1x enable command to disable 802.1X authentication globally. Usage There are no usage guidelines for this command. Guidelines Examples To enable 802.1X authentication globally: switch(config)#dot1x enable See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To enable the port state to auto: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x port-control auto See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Changing the quiet-period interval time to a number lower than the default can result in a faster Guidelines response time. Examples To change the interval time to 200 seconds: switch(config)#interface extengigabiethernet 0/16 switch(conf-if-te-0/16)#dot1x quiet-period 200 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to initiate the reauthentication on a specified interface. Usage There are no usage guidelines for this command. Guidelines Examples To initiate reauthentication on interface extengigabitethernet 0/16: switch#dot1x reauthenticate interface extengigabitethernet 0/16 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to enable reauthentication on a port. Usage There are no usage guidelines for this command. Guidelines Examples To enable reauthentication on a port: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x reauthentication See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To set the maximum number of reauthentication attempts to 5: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16))#dot1x reauthMax 5 To set the reauthentication maximum to the default value: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#no dot1x reauthMax See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Usage There are no usage guidelines for this command. Guidelines Examples To set 25 seconds as the amount of time between reauthorization attempts: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x timeout re-authperiod 25 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Use this command to set the authentication sever response timeout. Usage There are no usage guidelines for this command. Guidelines Examples To set 40 seconds as the switch-to-authentication server transmission time: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x timeout server-timeout 40 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
There are no usage guidelines for this command. Guidelines Examples To set 45 seconds as the switch-to-client retransmission time for the EAP request frame: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x timeout supp-timeout 40 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To set 34 as the number of seconds to wait for a response to an EAP-request or identity frame from the client before retransmitting the request: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x timeout tx-period 34 See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
To display all statistical information of the established session: switch>show dot1x session-info interface extengigabitethernet 0/16 802.1X Session info for te0/16 ------------------------------- User Name: testuser Session Time: 3 mins 34 secs Terminate Cause: Not terminated yet See Also none Dell Converged Enhanced Ethernet Command Reference 53-1002115-01...
Need help?
Do you have a question about the 8 and is the answer not in the manual?
Questions and answers