Dell MXL 10GbE Reference Manual page 1416

Switch i/o module
Table of Contents

Advertisement

module FC ports so that they appear to downstream server CNA ports as FCoE
Forwarder (FCF) ports on an FCoE network.
The following table describes the show fcoe-map brief output shown in the
example below.
Field
Fabric-Name
Fabric ID
VLAN ID
FC-MAP
FCF Priority
Config-State
Oper-State
The following table describes the show fcoe-map map-name output shown in
the example below.
Field
Fabric-Name
Fabric ID
VLAN ID
VLAN priority
1416
Description
Name of a SAN fabric.
The ID number of the SAN fabric to which FC traffic is
forwarded.
The dedicated FCoE VLAN used to transport FCoE storage
traffic between servers and a fabric over the NPIV proxy
gateway. The configured VLAN ID must be the same as the
fabric ID.
FCoE MAC address-prefix value - The unique 24-bit MAC
address prefix that identifies a fabric.
The priority used by a server to select an upstream FCoE
forwarder.
Indicates whether the configured FCoE and FC parameters
in the FCoE map are valid: Active (all mandatory FCoE and
FC parameters are correctly configured) or Incomplete
(either the FC-MAP value, fabric ID, or VLAN ID are not
correctly configured).
Operational status of link to the fabric: Up (link is up and
transmitting FC traffic), Down (link is down and not
transmitting FC traffic), Link-wait (link is up and waiting for
FLOGI to complete on peer FC port), or Removed (port has
been shut down).
Description
Name of a SAN fabric.
The ID number of the SAN fabric to which FC traffic is
forwarded.
The dedicated FCoE VLAN used to transport FCoE storage
traffic between servers and a fabric over the NPIV proxy
gateway. The configured VLAN ID must be the same as the
fabric ID.
FCoE traffic uses VLAN priority 3. (This setting is not user-
configurable.)
FC Flex IO Modules

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxl 40gbe

Table of Contents