Dcb Stack-Unit Pfc-Buffering Pfc-Port-Count Pfc-Queues - Dell MXL 10GbE Reference Manual

Switch i/o module
Table of Contents

Advertisement

dcb stack-unit pfc-buffering pfc-port-count pfc-queues

Configure the PFC buffer for all port pipes in a specified stack unit by specifying the port-pipe number,
number of PFC-enabled ports, and number of configured lossless queues.
Syntax
dcb stack-unit stack-unit-id [port-set port-set-id] pfc-
buffering pfc-ports {1-56} pfc-queues {1-2}
To remove the configuration for the PFC buffer on all port pipes in a specified stack
unit, use the no dcb stack-unit stack-unit-id [port-set port-set-
id] pfc-buffering pfc-ports pfc-queues command.
Parameters
stack-unit-id
port-set
pfc-ports
{1-56}
pfc-queues
{1-2}
Command
CONFIGURATION
Modes
Command
Version 9.2(0.0)
History
Version 8.3.16.1
Usage
If you configure PFC on a 40GbE port, count the 40GbE port as four PFC-enabled
Information
ports in the pfc-port number you enter in the command syntax.
To achieve lossless PFC operation, the PFC port count and queue number used for
the reserved buffer size that is created must be greater than or equal to the buffer
size required for PFC-enabled ports and lossless queues on the switch.
You must reload the stack or a specified stack unit (use the reload command in
EXEC Privilege mode) for the PFC buffer configuration to take effect.
Related
dcb stack-unit pfc-buffering pfc-port pfc-queues
Commands
all switches in the stack.
dcbx port-role
Configure the DCBX port role the interface uses to exchange DCB information.
Syntax
dcbx port-role {config-source | auto-downstream | auto-upstream
| manual}
1430
Enter the stack unit identification. The range is from 0 to 5.
Enter the port-set identification. The only valid port-set ID
(port-pipe number) on an MXL Switch is 0.
Enter the pfc-ports. The range is from 1 to 56.
Enter the pfc-queue number. The range is from 1 to 2.
Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
Introduced on the MXL 10/40GbE Switch IO Module.
PMUX Mode of the MXL 10/40GbE Switch I/O Module
— configures the PFC buffer for

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxl 40gbe

Table of Contents