Fcf-Priority - Dell MXL 10GbE Reference Manual

Switch i/o module
Table of Contents

Advertisement

Usage
In the fabric-id vlan command, the fabric and VLAN ID numbers must be the
Information
same.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must
be unique.
To remove a fabric-VLAN association from an FCoE map, enter the no fabric-id
vlan command.
You must first create a VLAN and then specify the configured VLAN ID in the
fabric-id vlan command. Otherwise, the following error message is displayed.
FTOS(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does
not exist
Related
fcoe-map
Commands
communication between servers and a SAN fabric.
show
FCoE maps.

fcf-priority

In an FCoE map, configure the priority used by a server CNA to select an upstream FCoE forwarder (FCF).
M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module
Syntax
fcf—priority priority
Parameters
priority
Defaults
128
Command
FCOE MAP
Modes
Command
Version 9.3(0.0)
History
Usage
The FCF priority you assign to an M I/O Aggregator and MXL 10/40GbE Switch with
Information
the FC Flex IO module is used by server CNAs to select an upstream FCF to use for
a fabric login (FLOGI).
To remove a configured FCF priority from an FCoE map, enter the no fcf-
priority command.
1408
— creates an FCoE map which contains the parameters used in the
fcoe-map— displays the Fibre Channel and FCoE configuration parameters in
Enter the priority assigned to the M I/O Aggregator and MXL
10/40GbE Switch with the FC Flex IO module NPIV proxy
gateway, which appears to a downstream server CNA as an
FCF. The range of FCF priority values is from 1 to 255.
Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.
FC Flex IO Modules

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxl 40gbe

Table of Contents