gateway so that they appear to downstream server CNA ports as FCoE forwarder
(FCF) ports on an FCoE network. When applied to FC and Ethernet ports on an
NPIV proxy gateway, an FCoE map allows the switch to operate as an FCoE-FC
bridge between an FC SAN and an FCoE network by providing FCoE-enabled
servers and switches with the necessary parameters to log in to a SAN fabric. Use
the fcoe-map command to create an FCoE map.
On an M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module
NPIV proxy gateway, you cannot apply an FCoE map on fabric-facing FC ports and
server-facing Ethernet ports.
After you apply an FCoE map on an FC interface, when the port is enabled (no
shutdown), the NPIV proxy gateway starts sending FIP multicast advertisements on
behalf of the FC port to downstream servers in order to advertise the availability of
a new FCF port on the FCoE VLAN.
To remove an FCoE map from an FC interface, enter the no fabric map-name
command in Interface configuration mode.
Related
fcoe-map
Commands
communication between servers and a SAN fabric.
show
FCoE maps.

fabric-id vlan

In an FCoE map, configure the association between the dedicated VLAN used to carry FCoE traffic
between servers and a SAN, and the fabric where the desired storage arrays are installed.
M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module
Syntax
fabric-id fabric-num vlan vlan-id
Parameters
fabric-id
fabric-num
vlanvlan-id
Defaults
None
Command
FCOE MAP
Modes
Command
Version 9.3(0.0)
History
FC Flex IO Modules
— creates an FCoE map which contains the parameters used in the
fcoe-map— displays the Fibre Channel and FCoE configuration parameters in
Enter a fabric ID number that is the same as the ID number
of the dedicated VLAN used to carry FCoE storage traffic to
the fabric specified in the FCoE map. You can enter a fabric
ID in the range 1–4094.
Enter the ID number of the dedicated VLAN used to carry
FCoE storage traffic between servers and a SAN fabric and
specified with the vlan command in the FCoE map.
Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.