I_act abs val unsmoothed
r0068[0]
n_act smoothed with p0045
r0063[1]
<2>
n_act smooth
r0063
<1>
State of breaking
<1> Only for SERVO.
<2> Only for VECTOR.
<3> Only if p0610.12 = 1.
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Thermal motor model 3
Activate thermal motor model 3
p0612.2[M](0)
Thermal motor model 3
Only for:
synchronous motors
<3>
Mot temp resp
p0610[M] (12)
3
4
Mot T_copper
F thresh fig p5391
r0632[M]
r5399
1
0
Mot T_stator
A thresh fig p5390
r0631[M]
r5398
1
Mot T_rotor
r0633[M]
0
r0632 – r5397
· 100 [%]
r5398 – r5397
5
6
fp_8019_54_eng.vsd
23.12.15 V04.08.00
192.00 ms
1
[8016.6]
T
0
A07012
"1/3 Thermal motor
model overtemperature"
[8016.1]
Mot_utiliz therm
r0034
7
8
Function diagram