Δ
10. SHOW
EC_TRAINING
This command is used to display the training feature of Echo Canceller (EC). Echo Canceller Feature is
used to prevent initial Echo (ranging from 500 to 1ms) from occurring in the beginning of speech to PBX
MG-PRI(SIP)>SHOW EC_TRAINING
EC Training Feature is ON.
Δ
11. SHOW
FAX_ECM
This command is used to display the setting of FAX ECM.
MG-PRI(SIP)>SHOW FAX_ECM
Fax ecm is OFF.
12. SHOW
Δ
FAXERRORDETECT
This command is used to display an available time to be switched to FAX.
MG-PRI(SIP)>SHOW FAXERRORDETECT
FAX Enable Timer is 1 minute.
13. SHOW
Δ
HC_RCV_TIMER
This command is used to display the time for timeout in receiving health check.
MG-PRI(SIP)>SHOW HC_RCV_TIMER
Health-Check Receive Timer Timeout is 150 seconds.
14. SHOW
Δ
INTERFACE
This command is used to display the connection mode of LAN interface.
MG-PRI(SIP)>SHOW INTERFACE
Setting: Auto-negotiation
Status: Speed is 100Mbps, DUPLEX:HALF
15. SHOW
Δ
IPADDRESS
This command is used to display the IP address of LAN interface.
MG-PRI(SIP)>SHOW IPADDRESS
IP Address
Subnetmask
Default Gateway
222.1.12.3
255.255.255.0
222.1.12.254
VOL.2-1117
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]
The current setting is displayed.
The current setting is displayed.
The current setting is displayed.
The current setting is displayed.
The current setting is displayed.
The current setting is displayed.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents