20. SET
PADP1
[P2]
This command is used to specify PAD data for PRI (1.5M). Before using this command, set Flexible (1) in
PAD selection of SET PAD0. For more information about the procedures, refer to the next page. To make
this assignment effective, it is required to execute the "SAVE" command and to restart before exiting the
maintenance command. The following is an example of PAD1.
When P2 is not entered:
MG-PRI(SIP)>SET PAD1
Flexible PAD #1-Recv((-16db)-(20dB): 0):0
Flexible PAD #1-Send((-16db)-(20dB): 0):0
set value is 0x0000
setting succeeded.
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]
P1-Specifying a PAD number
1-4=PAD Number
The available PAD number varies depending on the
ARTD settings (Telephony Server side).
ARTD PAD
0/4
1
2
3
5/6/7
1) Specify Flexible PAD for receiving
(ISDN Network→MG)
(-16db)-(20db): Flexible PAD for receiving
(default value: 0)
Send or receive might be 0 depending on
Note:
the PAD control setting.
2) Specify Flexible PAD for sending
(MG→ISDN Network
(-16db)-(20db): Flexible PAD for sending
(default value: 0)
0:
0dB
1:
1dB (LOSS)
2:
2dB (LOSS)
:
18:
18dB (LOSS)
19:
19dB (LOSS)
20:
20dB (LOSS)
Result is displayed.
VOL.2-1101
AVAILABLE PAD NUMBER
PAD4
PAD1
PAD2
PAD3
Not available
-1:
-1dB (GAIN)
-2:
-2dB (GAIN)
-3:
-3dB (GAIN)
:
:
:
-14:
-14dB (GAIN)
-15:
-15dB (GAIN)
-16:
-16dB (GAIN)