NEC Univerge sv8500 Manual page 1362

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

Δ
Δ
25. SET
PRI_T1_3
[P1]
This command is used to specify signaling data for PRI (1.5M). To make this assignment effective, it is
required to execute the "SAVE" command and to restart before exiting the maintenance command.
When P1 is not entered:
MG-PRI(SIP)>SET
PRI_T1_3
4K Data Link
G.704 Mode
BOS/MOS Operation
Signaling A Logic-Recv
Signaling Pattern-Recv
Signaling A Logic-Send
Signaling Pattern-Send
set value is 0x00CC
setting succeeded.
When P1=00CC:
MG-PRI(SIP)>SET PRI_T1_3 00CC
set value is 0x00CC
setting succeeded.
1) Specify 4K Data Link
(0/1: 0):0
0=MOS (default)
1=BOS
2) Specify G.704 Mode
(0/1: 0):0
0=ITU-T G.704 (default)
1=JG.704
3) Specify BOS/MOS Operation
(0-3: 0):0
When 0 is specified for 4K Data Link:
0=Sending MOS Message periodically/
Receiving MOS Message (default)
1=Sending Mark /Receiving MOS Message
2=Sending MOS Flag /Receiving MOS Message
3=Sending MOS Flag /Not Receiving MOS Message
When 1 is specified for 4K Data Link
-When 0 is specified for G.704 Mode:
0=Sending 7E, 7E /Receiving BOS Message
1=Sending FF, FF /Receiving BOS Message
2=Sending FF, 7E /Receiving BOS Message
3=Sending FF, FF /Not Receiving BOS Message
-When 1 is specified for G.704 Mode:
0=Sending 7E, 7E /Receiving BOS Message
1=Sending 00, 00 /Receiving BOS Message
2=Sending 00, 00 /Receiving BOS Message
3=Sending 00, 00 /Not Receiving BOS Message
4) Specify Signaling A Logic-Recovery
(0/1: 1):1
1 (fixed)
5) Specify Signaling Pattern Recovery
(0-3: 2):2
2 (fixed)
6) Enable/Disable Signaling A Logic Sending
(0/1: 1):1
1 (fixed)
7) Specify Signaling Pattern Sending
(0-3: 2):2
2 (fixed)
Result is displayed.
P1-Specify a set value
0000-FFFF= Set value (default value: 00CC)
Result is displayed.
VOL.2-1109