NEC Univerge sv8500 Manual page 1352

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

Δ
Δ
19. SET
PAD0
[P1]
This command is used to specify PAD 0 data for PRI (1.5M). To make this assignment effective, it is re-
quired to execute the "SAVE" command and to restart before exiting the maintenance command.
When P1 is not entered:
MG-PRI(SIP)>SET PAD0
A-law/μ-law Setting
PAD Selection
PAD Control
PAD Pattern No.
Data PAD Pattern No.
set value is 0x0000
setting succeeded.
When P1=0000:
MG-PRI(SIP)>SET PAD0 0000
set value is 0x0000
setting succeeded.
The sending (snd) and receiving (rcv) values vary depending on PAD settings of ARTD (PBX settings) and PAD
Pattern Number. The following are divided into two sheets in the case of the
scribe the snd/rcv values:
1) Select a type of CODEC
(0-4: 0):0
0=MGC Control (PBX System Data) (default)
1=μ-law
2=A-law
3=Convert from A-law to μ-law
4=Convert from μ-law to A-law
2) Select a type of PAD selection
(0/1: 0):0
0=Standard (default)
1=Flexible
3) Select a type of PAD Control
(0-3: 0):0
0=Receiving Control (MG
fault)
1=Sending Control (ISDN Network
2=Fixed to ARTD
3=Sending/Receiving Control
4) Select the number of PAD Pattern
(0-4: 0):0
0-4=Pattern Number (default value: 0)
* For more detailed information about the PAD patterns,
see the tables below.
5) Select the number of Data PAD Pattern
(0-4: 0):0
0=64K(default)
1-4=Not available
Result is displayed.
P1-Specifying a set value
Result is displayed.
VOL.2-1099
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]
0000-FFFF= Set value (default value: 0000)
A-Law/μ-Law
ISDN Network) (de-
MG)
settings, which de-

Hide quick links: