NEC Univerge sv8500 Manual page 1368

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

When P1=1 (Primary DRS) is not entered:
MG-PRI(SIP)>SHOW DRSADDRESS
Primary
DRS Address 10.41.1.100, Port 3456
Secondary DRS Address 10.41.1.101, Port 3457
Tertiary
DRS Address 10.41.1.102, Port 3458
Fourth
DRS Address 10.41.1.103, Port 3459
When P1=1 (Primary DRS) is entered:
MG-PRI(SIP)>SHOW DRSADDRESS 1
Primary DRS Address 10.41.1.100, Port 3456
6.
SHOW
Δ
DRSQOS
This command is used to display the QOS setting for DRS session. The following is an example in the case
of TOS setting.
MG-PRI(SIP)>SHOW DRSQOS
DRS QoS is 0xC0.(QOS=TOS)
PRECEDENCE=6
DELAY=0
THROUGHPUT=0
RELIABILITY=0
COST=0
7.
SHOW
Δ
DTMF_IN
This command is used to display the current setting of DTMF relay of in-band signaling.
MG-PRI(SIP)>SHOW DTMF_IN
Inband DTMF Relay is OFF.
Δ
8.
SHOW
E_T_TIME
This command is used to display an executing time of EC Training feature.
MG-PRI(SIP)>SHOW E_T_TIME
EC Training Feature Time is 32.
9.
SHOW
Δ
E_T_WAITTIME
MG(PRI) (1.5M) [SCA-24PRIA/MG-24PRIA]
The current setting is displayed.
P1-Select the DRS to be displayed.
1=Primary DRS
2=Secondary DRS
3=Tertiary DRS
4=Fourth DRS
The current setting is displayed.
The current setting is displayed.
- QOS
- PRECEDENCE (0-7 (low-high))
- Delay (0/1=Normal/Delay)
- THROUGHPUT (0/1=Normal/High Throughput)
- RELIABILITY (0/1=Normal/High Reliability)
- COST (0/1=Normal/Cost Precedence)
- DSCP (0-63)
The current setting is displayed.
The current setting is displayed.
VOL.2-1115