Quick Save

The Quick Save front-panel key repeats the most recent save that was performed from the Save menu,
with the following exceptions:
• Register saves are not remembered as Saves for the purpose of the Quick Save function
• If the current measurement does not support the last non-register save that was performed, an
informational message is generated, "File type not supported for this measurement"
Quick Save repeats the last type of qualified save (that is, a save qualified by the above criteria) in the last
save directory by creating a unique filename using the Auto File Naming algorithm described below.
If Quick Save is pressed after startup and before any qualified Save has been performed, the Quick Save
function performs a Screen Image save using the current settings for Screen Image saves (current theme,
current directory), which then becomes the "last save" for the purpose of subsequent Quick Saves.
The Auto File Naming feature automatically generates a file name for use when saving a file. The filename
consists of a prefix and suffix separated by a dot, as is standard for the Windows® file system.  A default
prefix exists for each of the available file types:
Type
State
Trace + State
Screen
Amplitude Corrections
Traces
Limit Lines
Measurement Result
Capture Buffer
A four digit number is appended to the prefix to create a unique file name. The numbering sequence starts
at 0000 within each Mode for each file type and updates incrementally to 9999, then wraps to 0000 again.
It remembers where it was through a Mode Preset and when leaving and returning to the Mode. It is reset
by Restore Misc Defaults and Restore System Defaults and subsequent running of the instrument
application. So, for example, the first auto file name generated for State files is State_0000.state. The next
is State_0001, and so forth.
One of the key features of Auto File Name is that we guarantee that the Auto File Name will never conflict
with an existing file.The algorithm looks for the next available number. If it gets to 9999, then it looks for
holes. If it find no holes, that is no more numbers are available, it gives an error.
For example, if when we get to State_0010.state there is already a State_0010.state file in the current
directory, it advances the counter to State_0011.state to ensure that no conflict will exist (and then it
verifies that State_0011.state also does not exist in the current directory and advances again if it does, and
so forth).
EMI Receiver Mode Reference
Default Prefix
Menu
State_
(Save/Recall)
State_
(Save/Recall)
Screen_
(Save/Recall)
Ampcor_
(Import/Export)
Trace_
(Import/Export)
LLine_
(Import/Export)
MeasR_
(Import/Export)
CapBuf_
(Import/Export)
8  Frequency Scan Measurement
Quick Save
521

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxa n9030aMxa n9020aExa n9010aCxa n9000aEmi n9038a

Table of Contents