Limit

This key selects Limit Lines as the data type to be imported.  When pressed a second time, it brings up the
Limits Menu, which lets you select into which Limit the data will be imported.
Key Path
Remote Command
Example
Dependencies
Couplings
Readback
Status Bits/OPC
dependencies
Initial S/W Revision
Default Directory
Specifies the default directory used for loading of Limit. If user is selected, the default recall directory is the
default (My Documents\EMI\data\xxx\Limits where xxx is the measurement name) or the last directory you
EMI Receiver Mode Reference
:MMEM:LOAD:TRAC DATA TRACE2, "myTrace2.csv" imports the 2nd trace from the file
myTrace2.csv in the current path. The default path is My Documents\EMI\data\xxx\traces where xxx
is the measurement name.
A trace cannot be recalled from a trace file that was exported with ALL traces selected.
A trace cannot be imported if the number of trace points in the file do not match the number of
sweep points currently set for the measurement.  If this happens, an error message is generated. 
Errors are reported if the file is empty or missing, or if the file type does not match, or if there is a
mismatch between the file type and the destination data type. 
If any error occurs while trying to load a file manually (as opposed to during remote operation), the
analyzer returns to the Import Data menu and the File Open dialog goes away.  
When a trace is imported, Trace Update is always turned OFF for that trace and Trace Display is
always turned ON.
1|2|3
Sequential - aborts the current measurement.
Prior to A.02.00
Recall, Data
:MMEMory:LOAD:LIMit LLINE1 | LLINE2 | LLINE3 | LLINE4 | LLINE5 |
LLINE6,<filename>
:MMEM:LOAD:LIM LLINE2, "myLimitLine2.csv" imports the 2nd Limit Line from the file
myLimitLine2.csv in the current path. The default path is depending on the Limit Default Directory
selection.
Errors are reported if the file is empty or missing, or if the file type does not match, or if there is a
mismatch between the file type and the destination data type.  If any of these occur during manual
operation, the analyzer returns to the Import Data menu and the File Open dialog goes away.
This key will only appear if you have the proper option installed in your instrument.
When a limit line is loaded from mass storage, it is automatically turned on.  This allows you to see
it, thus confirming the load. The Margin settings will match those set when the limit was saved
1|2|3|4|5|6
Sequential - aborts the current measurement
A.02.00