Selecting a detector for a meter (pressing the key or sending a [:SENS]:MET:DET command) puts the
meter in On, even if that detector was already selected.
Voltage averaging will be used.
POSitive|QPEak|EAVerage
Saved in instrument state
Peak|Quasi Peak|EMI Average|RMS Average|Negative Peak
A.07.00
Remote command only
:SENSe1|SENSe2|[SENSe]:DETector:RECeiver[:FUNCtion] POSitive | NEGative
| RMS | AVERage | QPEak | CAVerage | CRMS,POSitive | NEGative | RMS |
AVERage | QPEak | CAVerage | CRMS,POSitive | NEGative | RMS | AVERage |
QPEak | CAVerage | CRMS
:SENSe1|SENSe2|[SENSe]:DETector:RECeiver[:FUNCtion]?
DET:REC AVER
This command is included for ESU compatibility. The suffix [1]|2 is irrelevant to the measurement,
they are added solely for remote language compatibility.
This SCPI can receive up to 3 detector types, the detector types are separated by a comma. The 2nd
and 3rd parameters in the command are optional. For example, for the case where two detectors are
sent, the command will look like this DET:REC POS,QPE. The first detector refers to meter 1
detector, while the latter refers to meter 2 detector.
This command is alias to [:SENSe]:METer[1]|2|3:DETector <DectectorType>, :DISPlay:METer[1]|2|3
[:STATe] ON.
POSitive
NEGative
RMS/ CRMS
CAVerage
AVERage
QPEak
The query will return the selected meter detector. 
CAV when EMI Average is selected.
CRMS when RMS Average is selected.
The number of detector parameters sent corresponds to the number of the meter being turned on,
which means if there are 2 detector parameters sent, meter 1 and 2 will be turned on, and meter 3
will be turned off.
POSitive
A.07.00
Peak
Negative Peak
RMS Average
EMI Average
Average
Quasi Peak
EMI Receiver Mode Reference