modified. In addition, you can use the Edit Register Names key under Save, State to enter custom names
for each register.
Registers are shared by all modes, so recalling from any one of the registers will cause a mode switch to
the mode that was active when the save to the Register occurred.
Although these 16 registers are the only registers available from the front panel, there are 128 state
registers available in the instrument. Registers 17–128 are only available from the SCPI interface, using
the *RCL command.
After the recall completes, the message "Register <register number> recalled" appears in the message
bar.  If you are in the Spectrum Analyzer Mode, and you are recalling a register that was saved in the
Spectrum Analyzer Mode, then after the recall, you will still be in the Recall Register menu. If the Recall
causes you to switch modes, then after the Recall, you will be in the Frequency menu.
If a requested register is empty an error is generated.
Key Path
Example
Range
Readback
Initial S/W Revision
Modified at S/W Revision

Data (Import)

Importing a data file loads data that was previously saved from the current measurement or from other
measurements and/or modes that produce compatible data files. The Import Menu only contains Data
Types that are supported by the current measurement.
Since the commonly exported data files are in .csv format, the data can be edited by the user prior to
importing. This allows you to export a data file, manipulate the data in Excel (the most common PC
Application for manipulating .csv files) and then import it.
Importing Data loads measurement data from the specified file into the specified or default destination,
depending on the data type selected. Selecting an Import Data menu key will not actually cause the
importing to occur, since the analyzer still needs to know from where to get the data. Pressing the Open
key in this menu brings up the Open dialog and Open menu that provides you with the options from where
to recall the data. Once a filename has been selected or entered in the Open menu, the recall occurs as
soon as the Open button is pressed.
Key Path
Mode
EMI Receiver Mode Reference
Recall, State
*RCL 1
1–16 from front panel, 1–128 from SCPI
Date and time with seconds resolution are displayed on the key
OR
A custom name of up to 30 characters entered using the Save, State,Edit Register Names key
OR
"(empty)" if no prior save operation has been performed to this register.
Prior to A.02.00
Prior to A.11.00
Recall
All
9  Strip Chart Measurement
Recall
673