Trace

This key selects Trace as the data type to be imported.  When pressed a second time, it brings up the Trace
Menu, which lets you select the Trace into which the data will be imported.
The trace file contains "meta" data which describes the state of the analyzer when the trace was exported
(see Trace File Contents).   If the meta data in the file does not match the current SA state, the "invalid data
indicator" (*) is displayed.
Key Path
Remote Command
Example
Dependencies
Couplings
Readback
Status Bits/OPC
dependencies
Initial S/W Revision
Limit
This key selects Limit Lines as the data type to be imported.  When pressed a second time, it brings up the
Limits Menu, which lets you select into which Limit the data will be imported.
Key Path
Remote Command
Example
EMI Receiver Mode Reference
Saved in instrument state.
User| Preloaded
"User"| "Preloaded"
A.13.00
Recall, Data
:MMEMory:LOAD:TRACe:DATA TRACE1 | TRACE2 | TRACE3 | TRACE4 | TRACE5 |
TRACE6,<filename>
:MMEM:LOAD:TRAC DATA TRACE2, "myTrace2.csv"  Imports the 2nd trace from the file
myTrace2.csv in the current path.   The default path is My Documents\SA\data\traces
For SA measurements, a trace cannot be recalled from a trace file that was exported with ALL traces
selected.
A trace cannot be imported if the number of trace points in the file do not match the number of
sweep points currently set for the measurement.  If this happens, an error message is generated. 
Errors are reported if the file is empty or missing, or if the file type does not match, or if there is a
mismatch between the file type and the destination data type. 
If any error occurs while trying to load a file manually (as opposed to during remote operation), the
analyzer returns to the Import Data menu and the File Open dialog goes away.  
When a trace is imported, Trace Update is always turned OFF for that trace and Trace Display is
always turned ON.
Selected Trace
Sequential - aborts the current measurement.
Prior to A.02.00
Recall, Data
:MMEMory:LOAD:LIMit LLINE1 | LLINE2 | LLINE3 | LLINE4 | LLINE5 |
LLINE6,<filename>
:MMEM:LOAD:LIM LLINE2, "myLimitLine2.csv" imports the 2nd Limit Line from the file
10  Monitor Spectrum Measurement