Time (Remote Command Only)

Sets or queries the time in the instrument.
Mode
Remote Command
Example
Notes
Initial S/W Revision
Power On
Enables you to select how the instrument should power on. The options are: Mode and Input/Output
Defaults, User Preset and Last State.
Key Path
Mode
Remote Command
Example
Preset
State Saved
Backwards
Compatibility SCPI
Backwards Compatibility
EMI Receiver Mode Reference
:SYST:DATE "2006,05,26"
<year> is the four digit representation of year. (for example, 2006)
<month> is the two digit representation of year. (for example. 01 to 12)
<day> is the two digit representation of day. (for example, 01 to 28, 29, 30, or 31) depending on the
month and year
Unless the current account has Power User or Administrator privileges, an error will be generated by
this command and no action will be taken.
Prior to A.02.00
All
:SYSTem:TIME "<hour>,<minute>,<second>"
:SYSTem:TIME?
:SYST:TIME "13,05,26"
<hour> is the two digit representation of the hour in 24 hour format
<minute> is the two digit representation of minute
<second> is the two digit representation of second
Unless the current account has Power User or Administrator privileges, an error will be generated by
this command and no action will be taken.
Prior to A.02.00
System
All
:SYSTem:PON:TYPE MODE|USER|LAST
:SYSTem:PON:TYPE?
:SYST:PON:TYPE MODE
This is unaffected by a Preset but is set to Mode on a "Restore System Defaults->All"
No
:SYSTem:PON:TYPE PRESet
the "PRESet" parameter is supported for backward compatibility only and behaves the same as
MODE.