Low Band - Keysight x-series User Reference Manual

Signal analyzer
Hide thumbs Also See for x-series:
Table of Contents

Advertisement

Off
Turns the internal preamp off
Key Path
Example
Readback
Initial S/W Revision

Low Band

Sets the internal preamp to use only the low band.
The frequency range of the installed (optional) low-band preamp is displayed in square brackets on the
Low Band key label.
Key Path
Example
Readback
Initial S/W Revision
Full Range
Sets the internal preamp to use its full range. The low band (0–3.6 GHz or 0–3GHz, depending on the
model) is supplied by the low band preamp and the frequencies above low band are supplied by the high
band preamp.
The frequency range of the installed (optional) preamp is displayed in square brackets on the Full Range
key label. If the high band option is not installed the Full Range key does not appear.
Key Path
Example
Readback
Initial S/W Revision
Backwards Compatibility SCPI Commands
"Internal Preamp State (Remote Command Only)" on page 394
"Grid Bottom Level (Remote Command Only)" on page 394
EMI Receiver Mode Reference
AMPTD Y Scale, Internal Preamp
:POW:GAIN OFF
Off
Prior to A.02.00
AMPTD Y Scale, Internal Preamp
:POW:GAIN ON
:POW:GAIN:BAND LOW
Low Band
Prior to A.02.00
AMPTD Y Scale, Internal Preamp
:POW:GAIN ON
:POW:GAIN:BAND FULL
Full Range
Prior to A.02.00