Operation; Instrument Setup - Leica iCON iCR70 User Manual

Table of Contents

Advertisement

4
4.1

Instrument setup

step-by-step

Operation

Operation
Instrument Setup
16541_001
A field controller is necessary for this procedure.
1.
Extend the tripod legs to allow for a comfortable working posture.
Position the tripod above the marked ground point, centring it as
good as possible. Ensure that the tripod plate is roughly horizontal.
2.
Fasten the tribrach and instrument onto the tripod.
Shield the instrument from direct sunlight and avoid uneven temper-
atures around the instrument.
3.
Turn on the instrument.
Connect the instrument to the field controller.
To activate the laser plummet, display the Compensator screen on
the field controller:
Select Devices from the Home Menu.
Tap the arrow button to the right of the device name.
Tap Compensator.
4.
Use the tribrach footscrews (a) to centre the plummet above the
ground point (b).
5.
Adjust the tripod legs to level the circular level (c).
6.
By using the electronic level, turn the tribrach footscrews (a) to level
the instrument precisely.
7.
Centre the instrument precisely over the ground point (b) by shifting
the tribrach on the tripod plate.
8.
Repeat steps 6. and 7. until the required accuracy is achieved.
c
a a
a
b
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icon icr80

Table of Contents