NEC Univerge sv8500 Manual page 1549

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

Restoring Configuration Data via TFTP
PCPro
Note 1: PCPro and Telnet both can be performed by single Personal Computer.
<Data Assignment on TFTP Server>
If the name of the backup config file is not sysdata, rename it to "sysdata".
STEP 1
Put the file in the root folder of TFTP server, and then start the TFTP server program.
STEP 2
Permit read behavior of this folder. For more information, refer to the appropriate manual at-
STEP 3
tached to the TFTP server program.
<Data Assignment on PCPro>
To search for the LENS of the target MG-T1(SIP), use the IPAN command.
STEP 4
To make environment setting for Telnet, use the ATUD command.
STEP 5
- Specify the LENS, which is belonging to the target MG-T1(SIP).
- Specify a user ID and a password, which are required for logging in MG-T1(SIP) via Telnet.
- Input any letter for USER LEVEL because MG-T1(SIP) does not use USERLEVEL.
- For VALID TIME, input a total of time required for completing this procedures.
A user ID and a password are temporary ones for download; you can specify them as you like.
Note:
After completing the above, click the Set button.
STEP 6
<Data Assignment on Telnet PC>
Start a command prompt and enter "telnet <MG-T1(SIP)'s IP Address>" to con-
STEP 7
nect MG-T1(SIP) via Telnet.
Log in to the target MG-T1(SIP) by entering userID and password, which are set in the
STEP 8
ATUD command.
(1) Make environment setting for TFTP
TFTP Server
SYSTEM
(2) Make environment setting for Telnet
IP Network
Note 1
Note 1
Telnet PC
Configdata
(4) Copy a config file (Backup File)
from TFTP server via TFTP
MG-T1(SIP)
ON
100M LINK
B
D
CONSOLE
PWR
ALM
LINE LB
Ether
LINE
VOL.2-1296
MG-T1(SIP) [SCA-24DTIA]
MUSIC
RESET

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents