Step4:
Setting configuration data on MG-SIP128 [MG-128SIPMGG]
(1)
On the activated MG-SIP128 [MG-128SIPMGG] with "mgsip login:" displayed, type "con-
fig" as the login name, and press Enter key.
mgsip login:
(2)
Prompt "MG(SIP)>" appears: you are in data setting mode.
mgsip login:config
MG(SIP)>
(3)
Use configuration commands to set data: Follow the following.
17.3.1 Setting of Basic Assignment
Here explains procedures for setting of basic assignment of MG-SIP128 [MG-128SIPMGG].
Assign each configuration data of MG-SIP to default setting.
MG(SIP)> set default
Are you sure? Y/N=y
Config data default set.
Assign the configuration data. For details of each parameter, refer to ?MG-SIP config_template Data.
MG(SIP)> set config_template
Imput template pattern. (0-255):2
Are you sure? Y/N=y
Selected template is set.
Note:
To make this assignment effective, it is required to execute the "REBOOT" command to save the
configuration and restart the MG-SIP128 [MG-128SIPMGG].
Note 8:
When other than 0-6 is entered for the template pattern number, "Not used" is displayed.
17.3.2 Setting of IP Address
Here explains procedures for setting the number of ports that MG-SIP128 [MG-128SIPMGG] uses, and IP ad-
dresses and subnet masks for each port of MG-SIP128 [MG-128SIPMGG].
Each port of MG-SIP128 [MG-128SIPMGG] is used as follows:
Be sure to select "y".
Enter the template pattern number 2.
Note 8
Be sure to select "y".
Completing the setting of Basic Assignment.