display events
Table 18. Denied IP events — Continued
Event
Type
Event Description
1924
IP RRJ-No GRQ msg
rcvd
1925
IP RRJ-RQ: new LM
fail
1926
IP
RRJ-Authentication
fail
1927
IP RRJ-Invld station
type
1928
IP
RRJ-StnTyp/Protocl
err
1929
IP RRJ-No idx for
MMCmplx
555-233-119
Explanation
Registration rejected; did not
receive a Gatekeeper Request
message
Registration rejected; failure
creating a new Login Manager.
Possible cause:
No available heap memory to
create LoginMgr
Cannot start LoginMgr timer
Clock not set
Registration rejected:
authentication failure. The
password that the user entered
and the administered password on
the station screen do not match.
Registration rejected:
invalid set type
no Remote Office or IP Softphone
administration on the station
screen
Registration rejected: station type
and call signalling protocol are
inconsistent. The IP Softphone
should be defined as either of the
following:
DCP ext with call control equal to
IP Softphone
H.323 ext with call control equal to
none
Registration rejected:
dual-connected DCP set user
record is missing the index for the
multimedia complex.
Event
Event
Data 1
Data 2
UID
IP address
UID
IP address
UID
IP address
UID
Type
UID
Endpoint
type (3rd
and 2nd
nyble); call
signalling
protocol
(low nyble)
UID
IP address
Continued on next page
Issue 5 October 2002
231
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers