44 Chapter 6: ACSEI Server Configuration Commands
acsei timer monitor
Syntax
View
Parameters
Description
Examples
display acsei client info
Syntax
View
Parameters
Description
acsei timer monitor seconds
undo acsei timer monitor
ACSEI server view
seconds: Value of the monitoring timer that is used by the ACSEI server to
monitor the ACSEI clients. It ranges from 0 to 10 (in seconds), where 0
disables the ACSEI server from monitoring the ACSEI client.
Use the acsei timer monitor command to set the monitoring timer for
the ACSEI server to monitor the ACSEI client.
Use the undo acsei timer monitor command to restore the default.
By default, the monitoring timer is set to five seconds.
# Set the monitor timer for the ACSEI server to monitor the ACSEI client
to six seconds.
<SW5500G> system-view
System View: return to User View with Ctrl+Z.
[SW5500G] acsei server
[SW5500G-acsei-server] acsei timer monitor 6
display acsei client info [ client-id ]
Any view
client-id: ID of an ACSEI client, in the range of 1 to 7.
Use the display acsei client info command to display the ACSEI client
information.