REP 10.3 Inverter Motor
Parts List on PL 10.11
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
WARNING
Take care during this procedure. Motors will become hot during normal operation.
1.
Remove the inverter assembly, REP 10.2.
2.
Remove the inverter motor, Figure 1.
Figure 1 Inverter motor
Replacement
Replacement is the reverse of the removal procedure.
Repairs/Adjustments
REP 10.3, REP 10.4
3
Remove the inverter
motor
2
Remove 2 screws
1
Un-clip the support arm from the
shaft
REP 10.4 Inverter Path Solenoid
Parts List on PL 10.11
Removal
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the inverter assembly, REP 10.2.
2.
Remove upper baffle assembly, REP 10.7.
3.
Remove the diverter solenoid, Figure 1.
2
Remove 2 screws
Figure 1 Inverter path solenoid
August 2007
4-178
WARNING
WARNING
3
Remove the solenoid
1
Disconnect solenoid
harness
WorkCentre 5687 Family